Project Report: Thermal Performance of FIRSTLIFE House

The paper deals with selected thermal properties of a small building that was built during the international student competition Solar Decathlon 2021/2022 and is now part of the Living Lab in Wuppertal. It summarizes the essential information about the overall design of this wooden building with construction and technologies corresponding to the passive building standard. Built-in sensors and other equipment enable long-term monitoring of thermal parameters. Part of the information comes from the building operation control system. The thermal transmittance value for the perimeter wall matches calculated expectation well, even from a short period of time and not at an achievable perfectly steady state boundary condition. The (positive) difference between the calculated values and the measured ones did not exceed 0.015 W/(m2K). It was proven that even for such a small building with a very small heat demand, the heat transfer coefficient can be estimated alternatively from a co-heating test (measured electricity power for a fan heater) and from energy delivered to underfloor heating (calorimeter in heating system). Differences among both measurement types and calculation matched in the range ± 10%. In the last section, the dynamic response test is briefly described. The measured indoor air temperature curves under periodic dynamic loads (use of fan heater) are compared with the simulation results. The simulation model working with lumped parameters for each element of the building envelope was able to replicate the measured situation well, while its use does not require special knowledge of the user. In the studied case, the differences between measured and simulated air temperatures were less than 1 Kelvin if the first two to three days of the test period are ignored due to large thermal inertia. Finally, the measurement campaign program for the next period is outlined.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-11-13
DOI
https://doi.org/10.3390/buildings14113600
Citations
5
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
1.33

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Project Report: Thermal Performance of FIRSTLIFE House

Z. Malik, Jan Tywoniak, Kateřina Sojková, Kamil Staněk
5 citations
Buildings
Building Energy and Comfort Optimization
1.33
article

Project Report: Thermal Performance of FIRSTLIFE House

Z. Malik, Jan Tywoniak, Kateřina Sojková, Kamil Staněk
article en
5 citations

Abstract

The paper deals with selected thermal properties of a small building that was built during the international student competition Solar Decathlon 2021/2022 and is now part of the Living Lab in Wuppertal. It summarizes the essential information about the overall design of this wooden building with construction and technologies corresponding to the passive building standard. Built-in sensors and other equipment enable long-term monitoring of thermal parameters. Part of the information comes from the building operation control system. The thermal transmittance value for the perimeter wall matches calculated expectation well, even from a short period of time and not at an achievable perfectly steady state boundary condition. The (positive) difference between the calculated values and the measured ones did not exceed 0.015 W/(m2K). It was proven that even for such a small building with a very small heat demand, the heat transfer coefficient can be estimated alternatively from a co-heating test (measured electricity power for a fan heater) and from energy delivered to underfloor heating (calorimeter in heating system). Differences among both measurement types and calculation matched in the range ± 10%. In the last section, the dynamic response test is briefly described. The measured indoor air temperature curves under periodic dynamic loads (use of fan heater) are compared with the simulation results. The simulation model working with lumped parameters for each element of the building envelope was able to replicate the measured situation well, while its use does not require special knowledge of the user. In the studied case, the differences between measured and simulated air temperatures were less than 1 Kelvin if the first two to three days of the test period are ignored due to large thermal inertia. Finally, the measurement campaign program for the next period is outlined.

BuildingsVol. 14(11)
Czech Technical University in Prague (CZ)
České Vysoké Učení Technické v Praze
Affordable and clean energy
Openalex Percentile: Top 20%
Building Energy and Comfort Optimization
1.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.