Influence of Compressive Strength and Steel-Tube Thickness on Axial Compression Performance of Ultra-High-Performance Concrete-Filled Stainless-Steel Tube Columns Containing Coarse Aggregates

With the increasing use of concrete-filled steel tubular (CFST) structures, exposed steel tubes are highly susceptible to corrosion, posing potential safety hazards. This study innovatively proposes the use of stainless-steel tubes instead of traditional carbon-steel ones and introduces coarse aggregates into ultra-high-performance concrete (UHPC), forming a coarse aggregate-incorporated ultra-high-performance concrete-filled stainless-steel tube (CA-UFSST). The inclusion of coarse aggregates not only compensates for the shortcomings of UHPC but also enhances the overall mechanical performance of the composite structure. Twenty sets of specimens were designed to analyze the influence of four parameters, including the coarse aggregate content, compressive strength, stainless-steel-tube thickness, and stainless-steel type on the axial compression performance of UHPC. The experimental results indicate that the failure mode of UHPC is related to the confinement ratio. As the confinement ratio increases, the failure mode transitions from shear failure to bulging failure. The addition of coarse aggregates enhances the stiffness of the specimens. Furthermore, this paper discusses the applicability of six current codes in predicting the bearing capacity of CA-UFSST and finds that the European code exhibits the best prediction performance. However, as the confinement ratio increases, the prediction accuracy becomes notably insufficient. Therefore, it is necessary to establish a more accurate calculation model for the axial compression bearing capacity.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-11-13
DOI
https://doi.org/10.3390/buildings14113605
Citations
1
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.26

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Compressive Strength and Steel-Tube Thickness on Axial Compression Performance of Ultra-High-Performance Concrete-Filled Stainless-Steel Tube Columns Containing Coarse Aggregates

Yongfei Cao, Bei Wang, Li Guo, Yang Hu et al.
1 citations
Buildings
Structural Load-Bearing Analysis
0.26
article

Influence of Compressive Strength and Steel-Tube Thickness on Axial Compression Performance of Ultra-High-Performance Concrete-Filled Stainless-Steel Tube Columns Containing Coarse Aggregates

Yongfei Cao, Bei Wang, Li Guo, Yang Hu, Yingda Zhang, Haiyang Li, Wenrui Li, Wenting He, Mengqi Zhu, Zhaopeng Tang
article en
1 citations

Abstract

With the increasing use of concrete-filled steel tubular (CFST) structures, exposed steel tubes are highly susceptible to corrosion, posing potential safety hazards. This study innovatively proposes the use of stainless-steel tubes instead of traditional carbon-steel ones and introduces coarse aggregates into ultra-high-performance concrete (UHPC), forming a coarse aggregate-incorporated ultra-high-performance concrete-filled stainless-steel tube (CA-UFSST). The inclusion of coarse aggregates not only compensates for the shortcomings of UHPC but also enhances the overall mechanical performance of the composite structure. Twenty sets of specimens were designed to analyze the influence of four parameters, including the coarse aggregate content, compressive strength, stainless-steel-tube thickness, and stainless-steel type on the axial compression performance of UHPC. The experimental results indicate that the failure mode of UHPC is related to the confinement ratio. As the confinement ratio increases, the failure mode transitions from shear failure to bulging failure. The addition of coarse aggregates enhances the stiffness of the specimens. Furthermore, this paper discusses the applicability of six current codes in predicting the bearing capacity of CA-UFSST and finds that the European code exhibits the best prediction performance. However, as the confinement ratio increases, the prediction accuracy becomes notably insufficient. Therefore, it is necessary to establish a more accurate calculation model for the axial compression bearing capacity.

BuildingsVol. 14(11)
Xihua University (CN), UNSW Sydney (AU), Dongfang Electric Corporation (China) (CN), China State Construction Engineering (China) (CN)
Xihua University
Sustainable cities and communities
Openalex Percentile: Top 43%
Structural Load-Bearing Analysis
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.