Abstract 4117646: The Ultimate Test in Hemocompatibility: HeartMate3 Restart After Prolonged Pump Shut Down

Introduction: The HeartMate 3 (HM3) LVAD, was shown to have a higher survival free of hemocompatibility related adverse events (HRAE) compared to its predecessors (HM2, HVAD). Superior HM3 outcomes are attributed to wide blood flow pathways coupled with frictionless movement and intrinsic pulsatility, reducing shear stress and blood stasis. It is unknown if improved hemocompatibility can withstand pump restart after prolonged shutdown. We herein report a case of HM3 pump stoppage without subsequent HRAE. Case Presentation: A 41-year-old male underwent HVAD implant in 2019 for advanced non-ischemic cardiomyopathy. This was exchanged to HM3 for recurrent neurological events despite therapeutic anticoagulation. Ten months after exchange, he awakened one morning to find his LVAD had been off for an unknown period but had not heard any device alarms (85dB if on battery power, 165dB if on wall power). Since he felt well he changed to battery power resulting in immediate pump restart. Log file analysis showed pump stoppage 2 am – 10 am, without preceding low flow alarms or power elevations. Management and Outcomes: In the ER INR was 1.5 (2.8 one week prior) and systemic heparin was started. Evaluation included: 1) CT brain without acute infarcts 2) echocardiogram without intracardiac thrombus 3) CT Angiography with patency of the inflow cannula and outflow graft 4) stable serial LDH measurements. The controller was exchanged, and analysis noted normal function. 1-year later the patient is maintained on warfarin and aspirin 325mg without further HRAE. Given the patient’s neurologic history and pump stoppage event, we did not invoke ARIES trial guidance and thus continued aspirin. Conclusion: Pump stoppage occurs when there is complete battery depletion, disconnection of both power leads, or the percutaneous lead from system controller. Our case is unique in that the duration of pump shutdown was 8 hours and INR subtherapeutic, without HRAE in the background of neurologic events on HVAD support. It has been previously reported that complete outflow graft thrombosis can occur shortly after LVAD decommissioning. The HM3 User Manual recommends restarting the pump immediately if off for a few minutes and using clinical judgment for longer durations due to increased risk for thromboembolic events. Our case adds to the paucity of existing data on improved hemocompatibility of the HM3 during rare circumstances of the ultimate test in hemocompatibility: complete pump shut down.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4117646
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4117646: The Ultimate Test in Hemocompatibility: HeartMate3 Restart After Prolonged Pump Shut Down

Anas Jawaid, Hadi Beaini, Małgorzata Góral, Matthias Peltz et al.
Circulation
Congenital Heart Disease Studies
article

Abstract 4117646: The Ultimate Test in Hemocompatibility: HeartMate3 Restart After Prolonged Pump Shut Down

Anas Jawaid, Hadi Beaini, Małgorzata Góral, Matthias Peltz, Maryjane Farr, D. Varghese, Patrick J. O’Hara, E. Hardin, Faris Araj, Michele Edwards, Fizza Hussain, Melanie B. Thomas, Han Wool Kim, Ravi Patel, mary hightower, Paris Malensek
article en

Abstract

Introduction: The HeartMate 3 (HM3) LVAD, was shown to have a higher survival free of hemocompatibility related adverse events (HRAE) compared to its predecessors (HM2, HVAD). Superior HM3 outcomes are attributed to wide blood flow pathways coupled with frictionless movement and intrinsic pulsatility, reducing shear stress and blood stasis. It is unknown if improved hemocompatibility can withstand pump restart after prolonged shutdown. We herein report a case of HM3 pump stoppage without subsequent HRAE. Case Presentation: A 41-year-old male underwent HVAD implant in 2019 for advanced non-ischemic cardiomyopathy. This was exchanged to HM3 for recurrent neurological events despite therapeutic anticoagulation. Ten months after exchange, he awakened one morning to find his LVAD had been off for an unknown period but had not heard any device alarms (85dB if on battery power, 165dB if on wall power). Since he felt well he changed to battery power resulting in immediate pump restart. Log file analysis showed pump stoppage 2 am – 10 am, without preceding low flow alarms or power elevations. Management and Outcomes: In the ER INR was 1.5 (2.8 one week prior) and systemic heparin was started. Evaluation included: 1) CT brain without acute infarcts 2) echocardiogram without intracardiac thrombus 3) CT Angiography with patency of the inflow cannula and outflow graft 4) stable serial LDH measurements. The controller was exchanged, and analysis noted normal function. 1-year later the patient is maintained on warfarin and aspirin 325mg without further HRAE. Given the patient’s neurologic history and pump stoppage event, we did not invoke ARIES trial guidance and thus continued aspirin. Conclusion: Pump stoppage occurs when there is complete battery depletion, disconnection of both power leads, or the percutaneous lead from system controller. Our case is unique in that the duration of pump shutdown was 8 hours and INR subtherapeutic, without HRAE in the background of neurologic events on HVAD support. It has been previously reported that complete outflow graft thrombosis can occur shortly after LVAD decommissioning. The HM3 User Manual recommends restarting the pump immediately if off for a few minutes and using clinical judgment for longer durations due to increased risk for thromboembolic events. Our case adds to the paucity of existing data on improved hemocompatibility of the HM3 during rare circumstances of the ultimate test in hemocompatibility: complete pump shut down.

CirculationVol. 150(Suppl_1)
Methodist Richardson Medical Center (US), Southwestern Medical Center (US), The University of Texas Southwestern Medical Center (US)
Good health and well-being
Openalex Percentile: Top 69%
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.