Abstract 4121516: Efficacy of Sentinel Cerebral Embolic Protection Device in Transcatheter Aortic Valve Replacement: A Meta-Analysis of Randomized Controlled Trials and Propensity Score Matched Studies

Background: Transcatheter aortic valve replacement (TAVR) is frequently associated with stroke due to debris embolization. Although the risk of stroke with the newer-generation devices is lower, stroke still represents a significant cause of mortality and morbidity after TAVR. The Sentinel cerebral embolic protection (CEP) device (Boston Scientific) is a dual embolic filter device designed to capture debris dislodged during TAVR. The current literature concerning the efficacy of Sentinel CEP in the reduction of stroke in patients undergoing TAVR is limited and inconsistent. Aim: This meta-analysis aimed to compare clinical outcomes with Sentinel CEP device in patients undergoing TAVR. Methods: A comprehensive systematic literature search was performed on PubMed, Embase, Cochrane Library and Clinicaltrial.gov from inception until 1st May 2024 to retrieve randomized controlled trials (RCTs) and propensity-matched studies comparing TAVR with and without the Sentinel CEP device. Pooled odds ratios (OR) with 95% confidence intervals (CI) were calculated using the DerSimonian-Laird random-effects model, with a p-value of <0.05 considered statistically significant. Results: 6 studies with a total of 25,130 patients undergoing TAVR (12608: Sentinel CEP device; 12522: Without Sentinel CEP device) were included in this meta-analysis. The use of the Sentinel CEP device in TAVR was associated with a statistically significant lower risk of acute kidney injury [OR: 0.89; 95% CI: 0.81, 0.97; p=0.01]. The use of Sentinel CEP device in TAVR was associated with a statistically insignificant trend towards reduction in stroke [OR: 0.80; 95% CI: 0.58, 1.10; p=0.18], all-cause mortality [OR: 0.74; 95% CI: 0.51, 1.07; p=0.11], and major vascular complications [OR: 0.74; 95% CI: 0.46, 1.19; p=0.21]. Conclusion: The use of the Sentinel CEP device in patients undergoing TAVR does not lead to a statistically significant reduction in stroke, all-cause mortality, and major vascular complications; however, the risk of acute kidney injury is lower. Large, multicentric RCTs are warranted to corroborate the findings of this meta-analysis.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4121516
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4121516: Efficacy of Sentinel Cerebral Embolic Protection Device in Transcatheter Aortic Valve Replacement: A Meta-Analysis of Randomized Controlled Trials and Propensity Score Matched Studies

Hritvik Jain, Mushood Ahmed, Neha Pervez, Aman Goyal et al.
Circulation
Cardiac Valve Diseases and Treatments
article

Abstract 4121516: Efficacy of Sentinel Cerebral Embolic Protection Device in Transcatheter Aortic Valve Replacement: A Meta-Analysis of Randomized Controlled Trials and Propensity Score Matched Studies

Hritvik Jain, Mushood Ahmed, Neha Pervez, Aman Goyal, Debankur Dey, Siddhant Passey, A. Franco, Jyoti Jain, Ramez M. Odat, Jagriti Jha, Janhvi Shah, Nandan Patel
article en

Abstract

Background: Transcatheter aortic valve replacement (TAVR) is frequently associated with stroke due to debris embolization. Although the risk of stroke with the newer-generation devices is lower, stroke still represents a significant cause of mortality and morbidity after TAVR. The Sentinel cerebral embolic protection (CEP) device (Boston Scientific) is a dual embolic filter device designed to capture debris dislodged during TAVR. The current literature concerning the efficacy of Sentinel CEP in the reduction of stroke in patients undergoing TAVR is limited and inconsistent. Aim: This meta-analysis aimed to compare clinical outcomes with Sentinel CEP device in patients undergoing TAVR. Methods: A comprehensive systematic literature search was performed on PubMed, Embase, Cochrane Library and Clinicaltrial.gov from inception until 1st May 2024 to retrieve randomized controlled trials (RCTs) and propensity-matched studies comparing TAVR with and without the Sentinel CEP device. Pooled odds ratios (OR) with 95% confidence intervals (CI) were calculated using the DerSimonian-Laird random-effects model, with a p-value of <0.05 considered statistically significant. Results: 6 studies with a total of 25,130 patients undergoing TAVR (12608: Sentinel CEP device; 12522: Without Sentinel CEP device) were included in this meta-analysis. The use of the Sentinel CEP device in TAVR was associated with a statistically significant lower risk of acute kidney injury [OR: 0.89; 95% CI: 0.81, 0.97; p=0.01]. The use of Sentinel CEP device in TAVR was associated with a statistically insignificant trend towards reduction in stroke [OR: 0.80; 95% CI: 0.58, 1.10; p=0.18], all-cause mortality [OR: 0.74; 95% CI: 0.51, 1.07; p=0.11], and major vascular complications [OR: 0.74; 95% CI: 0.46, 1.19; p=0.21]. Conclusion: The use of the Sentinel CEP device in patients undergoing TAVR does not lead to a statistically significant reduction in stroke, all-cause mortality, and major vascular complications; however, the risk of acute kidney injury is lower. Large, multicentric RCTs are warranted to corroborate the findings of this meta-analysis.

CirculationVol. 150(Suppl_1)
Jordan University of Science and Technology (JO), Rawalpindi Medical University (PK), King Edward Memorial Hospital and Seth G.S. Medical College (IN), All India Institute of Medical Sciences Jodhpur (IN), KPC Medical College and Hospital (IN), Dow University of Health Sciences (PK), St. Luke's Hospital (US), UConn Health (US)
Good health and well-being
Openalex Percentile: Top 63%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.