Accuracy of O-RADS System in Differentiating Between Benign and Malignant Adnexal Masses Assessed via External Validation by Inexperienced Gynecologists

<b>Objective:</b> To evaluate the accuracy of the O-RADS system in differentiating between benign and malignant adnexal masses, as assessed by inexperienced gynecologists. <b>Methods:</b> Ten gynecologic residents attended a 20 h training course on the O-RADS system conducted by experienced examiners. Following the training, the residents performed ultrasound examinations on patients admitted with adnexal masses under supervision, recording the data in a database that included videos and still images. The senior author later accessed this ultrasound database and presented the cases offline to ten residents for O-RADS rating, with the raters being blinded to the final diagnosis. The efficacy of the O-RADS system by the residents and inter-observer variability were assessed. <b>Results:</b> A total of 201 adnexal masses meeting the inclusion criteria were evaluated, consisting of 136 (67.7%) benign masses and 65 (32.3%) malignant masses. The diagnostic performance of the O-RADS system showed a sensitivity of 90.8% (95% CI: 82.2-96.2%) and a specificity of 86.8% (95% CI: 80.4-91.8%). Inter-observer variability in scoring was analyzed using multi-rater Fleiss Kappa analysis, yielding Kappa indices of 0.642 (95% CI: 0.641-0.643). The false positive rate was primarily due to the misclassification of solid components in classic benign masses as O-RADS-4 or O-RADS-5. <b>Conclusions:</b> The O-RADS system demonstrates high diagnostic performance in distinguishing benign from malignant adnexal masses, even when used by inexperienced examiners. However, the false positive rate remains relatively high, mainly due to the over-interpretation of solid-appearing components in classic benign lesions. Despite this, inter-observer variability among non-expert raters was substantial. Incorporating O-RADS system training into residency programs is beneficial for inexperienced practitioners. This study could be an educational model for gynecologic residency training for other systems of sonographic features.

Authors

Institutions

Publication Details

Journal
Cancers
Published
2024-11-13
DOI
https://doi.org/10.3390/cancers16223820
Citations
5
Primary Topic
Ovarian cancer diagnosis and treatment
Type
article
Field-Weighted Citation Impact
2.69
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of O-RADS System in Differentiating Between Benign and Malignant Adnexal Masses Assessed via External Validation by Inexperienced Gynecologists

Theera Tongsong, Charuwan Tantipalakorn, Suchaya Luewan, Peeradech Buranaworathitikul et al.
5 citations
Cancers
Ovarian cancer diagnosis and treatment
2.69
article

Accuracy of O-RADS System in Differentiating Between Benign and Malignant Adnexal Masses Assessed via External Validation by Inexperienced Gynecologists

Theera Tongsong, Charuwan Tantipalakorn, Suchaya Luewan, Peeradech Buranaworathitikul, Yosagorn Porngasemsart, Veera Wisanumahimachai, Atiphoom Thiamkaew, Natthaphon Phoblap, Waranya Rugfoong, Nuttha Yotchana, Pakaporn Uthaichalanont, Thunthida Jiampochaman, Chayanid Kunanukulwatana
article en
5 citations

Abstract

<b>Objective:</b> To evaluate the accuracy of the O-RADS system in differentiating between benign and malignant adnexal masses, as assessed by inexperienced gynecologists. <b>Methods:</b> Ten gynecologic residents attended a 20 h training course on the O-RADS system conducted by experienced examiners. Following the training, the residents performed ultrasound examinations on patients admitted with adnexal masses under supervision, recording the data in a database that included videos and still images. The senior author later accessed this ultrasound database and presented the cases offline to ten residents for O-RADS rating, with the raters being blinded to the final diagnosis. The efficacy of the O-RADS system by the residents and inter-observer variability were assessed. <b>Results:</b> A total of 201 adnexal masses meeting the inclusion criteria were evaluated, consisting of 136 (67.7%) benign masses and 65 (32.3%) malignant masses. The diagnostic performance of the O-RADS system showed a sensitivity of 90.8% (95% CI: 82.2-96.2%) and a specificity of 86.8% (95% CI: 80.4-91.8%). Inter-observer variability in scoring was analyzed using multi-rater Fleiss Kappa analysis, yielding Kappa indices of 0.642 (95% CI: 0.641-0.643). The false positive rate was primarily due to the misclassification of solid components in classic benign masses as O-RADS-4 or O-RADS-5. <b>Conclusions:</b> The O-RADS system demonstrates high diagnostic performance in distinguishing benign from malignant adnexal masses, even when used by inexperienced examiners. However, the false positive rate remains relatively high, mainly due to the over-interpretation of solid-appearing components in classic benign lesions. Despite this, inter-observer variability among non-expert raters was substantial. Incorporating O-RADS system training into residency programs is beneficial for inexperienced practitioners. This study could be an educational model for gynecologic residency training for other systems of sonographic features.

CancersVol. 16(22)
Chiang Mai University (TH)
Openalex Percentile: Top 10%
Ovarian cancer diagnosis and treatment
2.69
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.