Protein extraction from yellow mealworm (Tenebrio molitor) assisted by pulsed electric fields: Effect on foaming properties

This study focuses on the use of Pulsed Electric Field (PEF) as a non-thermal technology to extract proteins from defatted Yellow Mealworm (T enebrio molitor ) meal. Additionally, the effect of PEF on the foaming properties of the extracted proteins was evaluated. An experimental design with two-factors and two levels, including the central point, was carried out: electric field (E: 1.5, 3.125 and 5 kV/cm) and number of pulses (N: 200, 1100 and 2000). The response variables studied were the protein extraction yield, the foam capacity (FC), and the foam stability constant (k) that was calculated by fitting the foam stability (FS) over the time to a first order exponential decrement equation. A positive effect of the crossed factor (EN) to the protein yield was found. Moreover, an increment of 27 % of the protein yield was observed when comparing PEF-based extracts to the control. Our results indicated that PEF contributed to reduce the molecular weight of the extracted proteins when compared with the control. Moreover, PEF induced modification of the protein structure as indicated by a reduction in fluorescence and content of β-sheet. The changes observed have an impact on the foaming properties measured, especially on FS which has decreased when applying PEF. • Extraction yield increased up to 27 % at 200 pulses and electric field strength of 1.25 kV/cm. • The application of PEF induced a decrease of the protein size. • Intrinsic fluorescence spectra signal decreased when increasing the electric field strength. • Secondary structure of the proteins is affected at electric field strength higher than 1.25 kV/cm.

Authors

Institutions

Publication Details

Journal
LWT
Published
2024-11-13
DOI
https://doi.org/10.1016/j.lwt.2024.117041
Citations
10
Primary Topic
Insect Utilization and Effects
Type
article
Field-Weighted Citation Impact
5.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Protein extraction from yellow mealworm (Tenebrio molitor) assisted by pulsed electric fields: Effect on foaming properties

Aberham Hailu Feyissa, Juana Pérez, Pedro J. García‐Moreno, Heidi Olander Petersen et al.
10 citations
LWT
Insect Utilization and Effects
5.40
article

Protein extraction from yellow mealworm (Tenebrio molitor) assisted by pulsed electric fields: Effect on foaming properties

Aberham Hailu Feyissa, Juana Pérez, Pedro J. García‐Moreno, Heidi Olander Petersen, Federico Casanova, Lucas Sales Queiroz
article en
10 citations

Abstract

This study focuses on the use of Pulsed Electric Field (PEF) as a non-thermal technology to extract proteins from defatted Yellow Mealworm (T enebrio molitor ) meal. Additionally, the effect of PEF on the foaming properties of the extracted proteins was evaluated. An experimental design with two-factors and two levels, including the central point, was carried out: electric field (E: 1.5, 3.125 and 5 kV/cm) and number of pulses (N: 200, 1100 and 2000). The response variables studied were the protein extraction yield, the foam capacity (FC), and the foam stability constant (k) that was calculated by fitting the foam stability (FS) over the time to a first order exponential decrement equation. A positive effect of the crossed factor (EN) to the protein yield was found. Moreover, an increment of 27 % of the protein yield was observed when comparing PEF-based extracts to the control. Our results indicated that PEF contributed to reduce the molecular weight of the extracted proteins when compared with the control. Moreover, PEF induced modification of the protein structure as indicated by a reduction in fluorescence and content of β-sheet. The changes observed have an impact on the foaming properties measured, especially on FS which has decreased when applying PEF. • Extraction yield increased up to 27 % at 200 pulses and electric field strength of 1.25 kV/cm. • The application of PEF induced a decrease of the protein size. • Intrinsic fluorescence spectra signal decreased when increasing the electric field strength. • Secondary structure of the proteins is affected at electric field strength higher than 1.25 kV/cm.

LWTVol. 213
Universidad de Granada (ES), Technical University of Denmark (DK)
Zero hunger
Openalex Percentile: Top 4%
Insect Utilization and Effects
5.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.