Abstract 4120821: Electrochemical Impedance Spectroscopy Unmasks High-Risk Atherosclerotic Features in Human Coronary Artery Disease

Background: Coronary plaque rupture remains the prominent mechanism of myocardial infarction. Accurate identification of rupture-prone plaque may improve clinical management. This study assessed the discriminatory performance of electrochemical impedance spectroscopy (EIS) in human cardiac explants to detect high-risk atherosclerotic features that portend rupture risk. Methods: In this single-center, prospective study, n=26 cardiac explants were collected for EIS interrogation of the three major coronary arteries. Vessels in which advancement of the EIS catheter without iatrogenic plaque disruption was rendered impossible were not assessed. N=61 vessels underwent EIS measurement and histological analyses. Plaques were dichotomized according to previously established high rupture-risk parameter thresholds. Diagnostic performance was determined via receiver operating characteristic areas-under-the-curve (AUC). Results: Necrotic cores were identified in n=19 vessels (median area 1.53 mm 2 ) with median fibrous cap thickness of 62 μm. Impedance was significantly greater in plaques with necrotic core area ≥1.75 mm 2 vs <1.75 mm 2 (19.8±4.4 kΩ vs 7.2±1.0 kΩ, P =0.019), fibrous cap thickness ≤65 μm vs >65 μm (19.1±3.5 kΩ vs 6.5±0.9 kΩ, P =0.004), and ≥20 macrophages per 0.3 mm-diameter high-power field (HPF) vs <20 macrophages per HPF (19.8±4.1 kΩ vs 10.2±0.9 kΩ, P=0.002). Impedance identified necrotic core area ≥1.75 mm 2 , fibrous cap thickness ≤65 μm, and ≥20 macrophages per HPF with AUCs of 0.889 (95% CI: 0.716–1.000) ( P =0.013), 0.852 (0.646—1.000) ( P =0.025), and 0.835 (0.577—1.000) ( P =0.028), respectively. Further, phase delay discriminated severe stenosis (≥70%) with an AUC of 0.767 (0.573—0.962) ( P =0.035). Conclusions: EIS discriminates high-risk atherosclerotic features that portend plaque rupture in human coronary artery disease and may serve as a complementary modality for angiography-guided atherosclerosis evaluation.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4120821
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4120821: Electrochemical Impedance Spectroscopy Unmasks High-Risk Atherosclerotic Features in Human Coronary Artery Disease

Michael C. Fishbein, René R. Sevag Packard, Peyman Benharash, Yas Sanaiha et al.
Circulation
Electrochemical sensors and biosensors
article

Abstract 4120821: Electrochemical Impedance Spectroscopy Unmasks High-Risk Atherosclerotic Features in Human Coronary Artery Disease

Michael C. Fishbein, René R. Sevag Packard, Peyman Benharash, Yas Sanaiha, Michael Chen, Yuan Luo, Krit Suwanaphoom
article en

Abstract

Background: Coronary plaque rupture remains the prominent mechanism of myocardial infarction. Accurate identification of rupture-prone plaque may improve clinical management. This study assessed the discriminatory performance of electrochemical impedance spectroscopy (EIS) in human cardiac explants to detect high-risk atherosclerotic features that portend rupture risk. Methods: In this single-center, prospective study, n=26 cardiac explants were collected for EIS interrogation of the three major coronary arteries. Vessels in which advancement of the EIS catheter without iatrogenic plaque disruption was rendered impossible were not assessed. N=61 vessels underwent EIS measurement and histological analyses. Plaques were dichotomized according to previously established high rupture-risk parameter thresholds. Diagnostic performance was determined via receiver operating characteristic areas-under-the-curve (AUC). Results: Necrotic cores were identified in n=19 vessels (median area 1.53 mm 2 ) with median fibrous cap thickness of 62 μm. Impedance was significantly greater in plaques with necrotic core area ≥1.75 mm 2 vs <1.75 mm 2 (19.8±4.4 kΩ vs 7.2±1.0 kΩ, P =0.019), fibrous cap thickness ≤65 μm vs >65 μm (19.1±3.5 kΩ vs 6.5±0.9 kΩ, P =0.004), and ≥20 macrophages per 0.3 mm-diameter high-power field (HPF) vs <20 macrophages per HPF (19.8±4.1 kΩ vs 10.2±0.9 kΩ, P=0.002). Impedance identified necrotic core area ≥1.75 mm 2 , fibrous cap thickness ≤65 μm, and ≥20 macrophages per HPF with AUCs of 0.889 (95% CI: 0.716–1.000) ( P =0.013), 0.852 (0.646—1.000) ( P =0.025), and 0.835 (0.577—1.000) ( P =0.028), respectively. Further, phase delay discriminated severe stenosis (≥70%) with an AUC of 0.767 (0.573—0.962) ( P =0.035). Conclusions: EIS discriminates high-risk atherosclerotic features that portend plaque rupture in human coronary artery disease and may serve as a complementary modality for angiography-guided atherosclerosis evaluation.

CirculationVol. 150(Suppl_1)
State Key Laboratory of Transducer Technology (CN), Shanghai Institute of Microsystem and Information Technology (CN)
Reduced inequalities
Openalex Percentile: Top 82%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.