Abstract 4134945: Biomechanical Impact of Crossing Neochords In Mitral Valve Repair Using Ex Vivo Mitral Valve Prolapse Models

Background: Neochord repair is a common technique to mitigate mitral regurgitation (MR). Certain techniques, such as the loop technique, purposefully anchor all neochords to one papillary muscle head, generating crossed configurations. The objective was to evaluate the impact of crossing neochord on mitral valve (MV) biomechanics using ex vivo mitral valve prolapse (MVP) models. Methods: Twenty-four healthy porcine MVs were explanted. The valves were randomly assigned to generate A2 or P2 MVP models by transecting A2 or P2 primary and secondary native chords. For each model, the valves were further randomly assigned to neochord repair by crossing the medial-lateral plane or the anterior-posterior plane. Fiber Bragg grating force sensors were mounted to measure chordal forces. Data were collected using an ex vivo heart simulator for baseline, MVP, and neochord repair in the native and the crossed configuration. Statistical analysis was performed using repeated measures analysis of variance with post-hoc correction. Results: In the P2 MVP model, AP crossed configuration was effective in reducing MR (p=.003) compared with the native configuration (p=.004), but the medial-laterally (ML) crossed configuration was not effective in reducing MR (p=.07) compared with the native configuration (p=.05). In the A2 MVP model, anterior-posteriorly crossed configuration was associated with increased average neochordal force compared with the native configuration (0.16±0.06N vs. 0.09±0.07N, p=.05). The ML crossed configuration was also associated with increased average neochordal force compared with the native configuration (0.05±0.03N vs.0.03±0.03N, p=.03). Peak native secondary chordal forces were increased in the ML crossed configuration compared with the native configuration (0.76±0.45N vs. 0.61±0.38N, p=.05). No differences between the crossed and native configurations were observed in the P2 MVP model. Conclusions: Differences exist in P2 MVP model hemodynamics and A2 MVP model chordal forces when neochords were crossed compared with the native configurations. These findings may provide important biomechanics insight regarding neochord implantation techniques and repair durability.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4134945
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4134945: Biomechanical Impact of Crossing Neochords In Mitral Valve Repair Using Ex Vivo Mitral Valve Prolapse Models

Shin Yajima, Stefan Elde, Y. Joseph Woo, Joon Bum Kim et al.
Circulation
Cardiac Valve Diseases and Treatments
article

Abstract 4134945: Biomechanical Impact of Crossing Neochords In Mitral Valve Repair Using Ex Vivo Mitral Valve Prolapse Models

Shin Yajima, Stefan Elde, Y. Joseph Woo, Joon Bum Kim, Yuanjia Zhu, Catherine A. Wu, Matthew Park, Chris Huynh
article en

Abstract

Background: Neochord repair is a common technique to mitigate mitral regurgitation (MR). Certain techniques, such as the loop technique, purposefully anchor all neochords to one papillary muscle head, generating crossed configurations. The objective was to evaluate the impact of crossing neochord on mitral valve (MV) biomechanics using ex vivo mitral valve prolapse (MVP) models. Methods: Twenty-four healthy porcine MVs were explanted. The valves were randomly assigned to generate A2 or P2 MVP models by transecting A2 or P2 primary and secondary native chords. For each model, the valves were further randomly assigned to neochord repair by crossing the medial-lateral plane or the anterior-posterior plane. Fiber Bragg grating force sensors were mounted to measure chordal forces. Data were collected using an ex vivo heart simulator for baseline, MVP, and neochord repair in the native and the crossed configuration. Statistical analysis was performed using repeated measures analysis of variance with post-hoc correction. Results: In the P2 MVP model, AP crossed configuration was effective in reducing MR (p=.003) compared with the native configuration (p=.004), but the medial-laterally (ML) crossed configuration was not effective in reducing MR (p=.07) compared with the native configuration (p=.05). In the A2 MVP model, anterior-posteriorly crossed configuration was associated with increased average neochordal force compared with the native configuration (0.16±0.06N vs. 0.09±0.07N, p=.05). The ML crossed configuration was also associated with increased average neochordal force compared with the native configuration (0.05±0.03N vs.0.03±0.03N, p=.03). Peak native secondary chordal forces were increased in the ML crossed configuration compared with the native configuration (0.76±0.45N vs. 0.61±0.38N, p=.05). No differences between the crossed and native configurations were observed in the P2 MVP model. Conclusions: Differences exist in P2 MVP model hemodynamics and A2 MVP model chordal forces when neochords were crossed compared with the native configurations. These findings may provide important biomechanics insight regarding neochord implantation techniques and repair durability.

CirculationVol. 150(Suppl_1)
Piedmont University (US), Stanford University (US)
Openalex Percentile: Top 63%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.