Abstract 4129839: Successful Left Atrial Appendage Occlusion (LAAO) with WATCHMAN FLX via Transhepatic Approach

Left atrial appendage occlusion (LAAO) with the WATCHMAN FLX (Boston Scientific) has been proven to reduce stroke risk in patients with paroxysmal atrial fibrillation (PAF). Certain circumstances may preclude LAAO1. In this case, transhepatic vein access was used to successfully deploy a WATCHMAN FLX in a 72 year old male with PAF not on anticoagulation due to recent subdural hemorrhage and recurrent bilateral lower extremity deep venous thrombosis (DVT) post IVC filter placement. Recent attempt at LAAO was unsuccessful due to total occlusion of bilateral femoral veins (Figure 1 A-B) and inability to cross the IVC. Access to the inferior branch of the right hepatic vein was achieved by micropuncture technique at the right mid-axillary line at the level of the 12th rib, which was confirmed by venogram (Figure 2A). The 4F microsheath was upsized to 16F. Intraoperative TEE was used for device sizing and delivery (Figure 3A). The transseptal sheath and dilator were positioned in the right atrium at the level of the fossa ovalis (Figure 3B) before successfully crossing into the left atrium (Figure 2B). After confirming placement (Figure 3C), a pigtail catheter was positioned within the LAA (Figure 3D) and an angiogram was performed (Figure 2C). A 24 mm WATCHMAN FLX was partially unsheathed and positioned (Figure 3E). Repeat LAA angiogram was performed through the WATCHMAN delivery sheath (Figure 2D). A Tug test was performed. The device was released (Figure 3F). Repeat venogram was performed to confirm location (Figure 2E) of the access site, and coil embolization closure of the venotomy access site was performed (Figure 2F). The patient was discharged the following day on dual antiplatelet (aspirin, clopidogrel) without complication. Venous access via right hepatic vein is a viable option for LAAO using the WATCHMAN FLX device.

Authors

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4129839
Citations
1
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4129839: Successful Left Atrial Appendage Occlusion (LAAO) with WATCHMAN FLX via Transhepatic Approach

Alex Card, Damian Valencia, Brian S. Schwartz, Gael Charbonne et al.
1 citations
Circulation
Atrial Fibrillation Management and Outcomes
0.40
article

Abstract 4129839: Successful Left Atrial Appendage Occlusion (LAAO) with WATCHMAN FLX via Transhepatic Approach

Alex Card, Damian Valencia, Brian S. Schwartz, Gael Charbonne, Karley Fischer, Omar Mitiek
article en
1 citations

Abstract

Left atrial appendage occlusion (LAAO) with the WATCHMAN FLX (Boston Scientific) has been proven to reduce stroke risk in patients with paroxysmal atrial fibrillation (PAF). Certain circumstances may preclude LAAO1. In this case, transhepatic vein access was used to successfully deploy a WATCHMAN FLX in a 72 year old male with PAF not on anticoagulation due to recent subdural hemorrhage and recurrent bilateral lower extremity deep venous thrombosis (DVT) post IVC filter placement. Recent attempt at LAAO was unsuccessful due to total occlusion of bilateral femoral veins (Figure 1 A-B) and inability to cross the IVC. Access to the inferior branch of the right hepatic vein was achieved by micropuncture technique at the right mid-axillary line at the level of the 12th rib, which was confirmed by venogram (Figure 2A). The 4F microsheath was upsized to 16F. Intraoperative TEE was used for device sizing and delivery (Figure 3A). The transseptal sheath and dilator were positioned in the right atrium at the level of the fossa ovalis (Figure 3B) before successfully crossing into the left atrium (Figure 2B). After confirming placement (Figure 3C), a pigtail catheter was positioned within the LAA (Figure 3D) and an angiogram was performed (Figure 2C). A 24 mm WATCHMAN FLX was partially unsheathed and positioned (Figure 3E). Repeat LAA angiogram was performed through the WATCHMAN delivery sheath (Figure 2D). A Tug test was performed. The device was released (Figure 3F). Repeat venogram was performed to confirm location (Figure 2E) of the access site, and coil embolization closure of the venotomy access site was performed (Figure 2F). The patient was discharged the following day on dual antiplatelet (aspirin, clopidogrel) without complication. Venous access via right hepatic vein is a viable option for LAAO using the WATCHMAN FLX device.

CirculationVol. 150(Suppl_1)
Good health and well-being
Openalex Percentile: Top 31%
Atrial Fibrillation Management and Outcomes
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.