Optimized detection modality for radio-frequency sensing with a double-resonance alignment magnetometer

In this work, we present a comprehensive and comparative analysis of two detection modalities, i.e., polarization rotation and absorption measurement of light, for a double-resonance alignment magnetometer (DRAM). We derive algebraic expressions for magnetometry signals based on the description of multipole moments. Experiments are carried out using a room-temperature paraffin-coated cesium-vapor cell and measuring either the polarization rotation or absorption of the transmitted laser light. A detailed experimental analysis of the resonance spectra is performed to validate the theoretical findings for various input parameters. The results signify the use of a single isotropic relaxation rate, thus simplifying the data analysis for optimization of the DRAM. The sensitivity measurements are performed and reveal that the polarization-rotation detection mode yields larger signals and better sensitivity than absorption measurement of light. Published by the American Physical Society 2024

Authors

Institutions

Publication Details

Journal
Physical Review Applied
Published
2024-11-13
DOI
https://doi.org/10.1103/physrevapplied.22.054033
Citations
3
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
1.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized detection modality for radio-frequency sensing with a double-resonance alignment magnetometer

Adil Meraki, L. Elson, Jan Kołodyński, M. Koźbiał et al.
3 citations
Physical Review Applied
Atomic and Subatomic Physics Research
1.01
article

Optimized detection modality for radio-frequency sensing with a double-resonance alignment magnetometer

Adil Meraki, L. Elson, Jan Kołodyński, M. Koźbiał, Ali Akbar, Kasper Jensen
article en
3 citations

Abstract

In this work, we present a comprehensive and comparative analysis of two detection modalities, i.e., polarization rotation and absorption measurement of light, for a double-resonance alignment magnetometer (DRAM). We derive algebraic expressions for magnetometry signals based on the description of multipole moments. Experiments are carried out using a room-temperature paraffin-coated cesium-vapor cell and measuring either the polarization rotation or absorption of the transmitted laser light. A detailed experimental analysis of the resonance spectra is performed to validate the theoretical findings for various input parameters. The results signify the use of a single isotropic relaxation rate, thus simplifying the data analysis for optimization of the DRAM. The sensitivity measurements are performed and reveal that the polarization-rotation detection mode yields larger signals and better sensitivity than absorption measurement of light. Published by the American Physical Society 2024

Physical Review AppliedVol. 22(5)
University of Nottingham (GB), University of Warsaw (PL)
Narodowe Centrum Nauki, Novo Nordisk Fonden, Horizon 2020 Framework Programme, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 24%
Atomic and Subatomic Physics Research
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.