A Sinusoidal Current Generator IC with 0.04% THD for Bio-Impedance Spectroscopy Using a Digital ΔΣ Modulator and FIR Filter

This paper presents a highly efficient, low-power, compact mixed-signal sinusoidal current generator (CG) integrated circuit (IC) designed for bioelectrical impedance spectroscopy (BIS) with low total harmonic distortion (THD). The proposed system employs a 9-bit sine wave lookup table (LUT) which is simplified to a 4-bit data stream through a third-order digital delta–sigma modulator (ΔΣM). Unlike conventional analog low-pass filters (LPF), which statically limit bandwidth, the finite impulse response (FIR) filter attenuates high-frequency noise according to the operating frequency, allowing the frequency range of the sinusoidal signal to vary. Additionally, the output of the FIR filter is applied to a 6-bit capacitive digital-to-analog converter (CDAC) with data-weighted averaging (DWA), enabling dynamic capacitor matching and seamless interfacing. The sinusoidal CG IC, fabricated using a 65 nm CMOS process, produces a 5 μA amplitude and operates over a wide frequency range of 0.6 to 20 kHz. This highly synthesizable CG achieves a THD of 0.04%, consumes 19.2 μW of power, and occupies an area of 0.0798 mm2. These attributes make the CG IC highly suitable for compact, low-power bio-impedance applications.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2024-11-13
DOI
https://doi.org/10.3390/electronics13224450
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Sinusoidal Current Generator IC with 0.04% THD for Bio-Impedance Spectroscopy Using a Digital ΔΣ Modulator and FIR Filter

Joonsung Bae, Soohyun Yun
Electronics
Electrical and Bioimpedance Tomography
article

A Sinusoidal Current Generator IC with 0.04% THD for Bio-Impedance Spectroscopy Using a Digital ΔΣ Modulator and FIR Filter

Joonsung Bae, Soohyun Yun
article en

Abstract

This paper presents a highly efficient, low-power, compact mixed-signal sinusoidal current generator (CG) integrated circuit (IC) designed for bioelectrical impedance spectroscopy (BIS) with low total harmonic distortion (THD). The proposed system employs a 9-bit sine wave lookup table (LUT) which is simplified to a 4-bit data stream through a third-order digital delta–sigma modulator (ΔΣM). Unlike conventional analog low-pass filters (LPF), which statically limit bandwidth, the finite impulse response (FIR) filter attenuates high-frequency noise according to the operating frequency, allowing the frequency range of the sinusoidal signal to vary. Additionally, the output of the FIR filter is applied to a 6-bit capacitive digital-to-analog converter (CDAC) with data-weighted averaging (DWA), enabling dynamic capacitor matching and seamless interfacing. The sinusoidal CG IC, fabricated using a 65 nm CMOS process, produces a 5 μA amplitude and operates over a wide frequency range of 0.6 to 20 kHz. This highly synthesizable CG achieves a THD of 0.04%, consumes 19.2 μW of power, and occupies an area of 0.0798 mm2. These attributes make the CG IC highly suitable for compact, low-power bio-impedance applications.

ElectronicsVol. 13(22)
Kangwon National University (KR)
Ministry of Trade, Industry and Energy, Korea Institute for Advancement of Technology
Affordable and clean energy
Openalex Percentile: Top 82%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.