Short cross-laminated timber plates subjected to out-of-plane loads

The use of cross-laminated timber (CLT) panels has increased significantly, driven by the demand for more sustainable structural solutions. When used in short spans, the load capacity of CLT panels can be significantly enhanced; however, their behaviour and failure mechanisms differ from those of large spans. This study evaluates the mechanical behaviour of short-span CLT panels made from Pinus taeda L. under out-of-plane loads, through experimental analyses on full-scale panels. Fourteen industrially manufactured panels were tested in four-point bending tests, using adhesive weights of 250 and 220 g/m². The values of maximum bending moment, shear force, and their respective resistances were analysed based on the observed failure modes. The transverse modulus of elasticity was determined using strain gauges. It was found that short panels, with a span-to-depth ratio of 9 ≤ l/h ≤ 12, exhibited bending moment and shear force failures, with no significant differences between adhesive weights. Discrepancies in shear resistance and stiffness values compared to existing standards suggest the need for reduced-specimen testing for greater accuracy.

Authors

Publication Details

Journal
Caderno Pedagógico
Published
2024-11-12
DOI
https://doi.org/10.54033/cadpedv21n12-104
Primary Topic
Structural Analysis of Composite Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Short cross-laminated timber plates subjected to out-of-plane loads

Nilson Tadeu Mascia, Bruno Fazendeiro Donadon, Ramon Vilela Bergamin
Caderno Pedagógico
Structural Analysis of Composite Materials
article

Short cross-laminated timber plates subjected to out-of-plane loads

Nilson Tadeu Mascia, Bruno Fazendeiro Donadon, Ramon Vilela Bergamin
article en

Abstract

The use of cross-laminated timber (CLT) panels has increased significantly, driven by the demand for more sustainable structural solutions. When used in short spans, the load capacity of CLT panels can be significantly enhanced; however, their behaviour and failure mechanisms differ from those of large spans. This study evaluates the mechanical behaviour of short-span CLT panels made from Pinus taeda L. under out-of-plane loads, through experimental analyses on full-scale panels. Fourteen industrially manufactured panels were tested in four-point bending tests, using adhesive weights of 250 and 220 g/m². The values of maximum bending moment, shear force, and their respective resistances were analysed based on the observed failure modes. The transverse modulus of elasticity was determined using strain gauges. It was found that short panels, with a span-to-depth ratio of 9 ≤ l/h ≤ 12, exhibited bending moment and shear force failures, with no significant differences between adhesive weights. Discrepancies in shear resistance and stiffness values compared to existing standards suggest the need for reduced-specimen testing for greater accuracy.

Caderno PedagógicoVol. 21(12)
Responsible consumption and production
Openalex Percentile: Top 80%
Structural Analysis of Composite Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Short cross-laminated timber plates subjected to out-of-plane loads — Nilson Tadeu Mascia, Bruno Fazendeiro Donadon, et al. · Caderno Pedagógico (2024) | TGRS Research Map | TGRS