Timepix3: single-pixel multi-hit energy-measurement behaviour

Abstract The event-driven hybrid-pixel detector readout chip, Timepix3, has the ability to simultaneously measure the time of an event on the nanosecond timescale and the energy deposited in the sensor. However, the behaviour of the system when two events are recorded in quick succession of each other on the same pixel was not studied in detail previously. We present experimental measurements, circuit simulations, and an empirical model for the impact of a preceding event on this energy measurements, which can result in a loss as high as 70%. Accounting for this effect enables more precise compensation, particularly for phenomena like timewalk. This results in significant improvements in time resolution — in the best case, multiple tens of nanoseconds — when two events happen in rapid succession.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-11-01
DOI
https://doi.org/10.1088/1748-0221/19/11/p11008
Citations
3
Primary Topic
CCD and CMOS Imaging Sensors
Type
article
Field-Weighted Citation Impact
0.63

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Timepix3: single-pixel multi-hit energy-measurement behaviour

Sebastian Trippel, Jochen Küpper, R. Ballabriga, H. Bromberger et al.
3 citations
Journal of Instrumentation
CCD and CMOS Imaging Sensors
0.63
article

Timepix3: single-pixel multi-hit energy-measurement behaviour

Sebastian Trippel, Jochen Küpper, R. Ballabriga, H. Bromberger, David Pennicard
article en
3 citations

Abstract

Abstract The event-driven hybrid-pixel detector readout chip, Timepix3, has the ability to simultaneously measure the time of an event on the nanosecond timescale and the energy deposited in the sensor. However, the behaviour of the system when two events are recorded in quick succession of each other on the same pixel was not studied in detail previously. We present experimental measurements, circuit simulations, and an empirical model for the impact of a preceding event on this energy measurements, which can result in a loss as high as 70%. Accounting for this effect enables more precise compensation, particularly for phenomena like timewalk. This results in significant improvements in time resolution — in the best case, multiple tens of nanoseconds — when two events happen in rapid succession.

Journal of InstrumentationVol. 19(11)
Universität Hamburg (DE), Deutsches Elektronen-Synchrotron DESY (DE), Center for Free-Electron Laser Science (DE), European Organization for Nuclear Research (CH)
Deutsche Forschungsgemeinschaft, Deutsches Elektronen-Synchrotron
Affordable and clean energy
Openalex Percentile: Top 31%
CCD and CMOS Imaging Sensors
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Timepix3: single-pixel multi-hit energy-measurement behaviour — Sebastian Trippel, Jochen Küpper, et al. · Journal of Instrumentation (2024) | TGRS Research Map | TGRS