Enhancing the Prediction of Locomotion Transition With High-Density Surface Electromyography

Prediction of transition between locomotion modes (e.g. moving from flat ground to stairs, etc) is vital for optimal interface with lower limb assistive technologies such as exoskeletons and prostheses. Inertial and bipolar electromyography (EMG) sensors have been investigated, but accuracy for clinical utility remains unresolved. This shortfall may be attributed to their limited capacity to detect subtle changes in muscle activations, particularly during the early stages of locomotion transitions (e.g., near the toe-off). In this study, we examined the effectiveness of two high-density surface electromyography (HDsEMG) sensors in detecting muscle activation changes during stair-related transitions. The results revealed that compared to bipolar EMG on the same muscles, HDsEMG-based methods increased transition prediction accuracy significantly from 70.2% to 91.1% when predicting at toe-off and from 89.8% to 99.2% when predicting with a delay of 400-ms relative to toe-off. This demonstrated the superior ability of HDsEMG to capture subtle muscle activation changes, especially during early transition stages. We also found reducing the electrode count to 21 per muscle only minimally impacted performance (88.3% accuracy at toe-off). This suggests distributing the same total number of electrodes across more muscles could potentially further improve prediction accuracy without increasing computational load. Moreover, by implementing image-inpainting signal processing, HDsEMG demonstrated robustness against the common issue of electrode signal loss. Even with 30% electrode detachment, prediction accuracy decreased only by 3%. We argue that HDsEMG offers a promising solution to bridge the gap in locomotion transition prediction for interface with assistive technology.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2024-11-13
DOI
https://doi.org/10.1109/jbhi.2024.3497658
Citations
4
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing the Prediction of Locomotion Transition With High-Density Surface Electromyography

Hsien-Yung Huang, Shibo Jing, Yongkun Zhao, Ravi Vaidyanathan et al.
4 citations
IEEE Journal of Biomedical and Health Informatics
Muscle activation and electromyography studies
0.74
article

Enhancing the Prediction of Locomotion Transition With High-Density Surface Electromyography

Hsien-Yung Huang, Shibo Jing, Yongkun Zhao, Ravi Vaidyanathan, Mélanie Jouaiti, Dario Farina, Zhenhua Yu
article en
4 citations

Abstract

Prediction of transition between locomotion modes (e.g. moving from flat ground to stairs, etc) is vital for optimal interface with lower limb assistive technologies such as exoskeletons and prostheses. Inertial and bipolar electromyography (EMG) sensors have been investigated, but accuracy for clinical utility remains unresolved. This shortfall may be attributed to their limited capacity to detect subtle changes in muscle activations, particularly during the early stages of locomotion transitions (e.g., near the toe-off). In this study, we examined the effectiveness of two high-density surface electromyography (HDsEMG) sensors in detecting muscle activation changes during stair-related transitions. The results revealed that compared to bipolar EMG on the same muscles, HDsEMG-based methods increased transition prediction accuracy significantly from 70.2% to 91.1% when predicting at toe-off and from 89.8% to 99.2% when predicting with a delay of 400-ms relative to toe-off. This demonstrated the superior ability of HDsEMG to capture subtle muscle activation changes, especially during early transition stages. We also found reducing the electrode count to 21 per muscle only minimally impacted performance (88.3% accuracy at toe-off). This suggests distributing the same total number of electrodes across more muscles could potentially further improve prediction accuracy without increasing computational load. Moreover, by implementing image-inpainting signal processing, HDsEMG demonstrated robustness against the common issue of electrode signal loss. Even with 30% electrode detachment, prediction accuracy decreased only by 3%. We argue that HDsEMG offers a promising solution to bridge the gap in locomotion transition prediction for interface with assistive technology.

IEEE Journal of Biomedical and Health InformaticsVol. 29(9)
University of Sussex (GB), University of Aberdeen (GB), Sussex County Community College (US), UK Dementia Research Institute (GB), Imperial College London (GB), University of Birmingham (GB)
Engineering and Physical Sciences Research Council
Climate action
Openalex Percentile: Top 31%
Muscle activation and electromyography studies
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.