Calibrating the Phased Array Antenna in a Reverberation Chamber

Identifying the power difference and phase shift of a phased array antenna (PAA) is essential in the PAA calibration. In this article, the ability of calibrating a PAA in a reverberation chamber (RC) is explored. Based on the proposed RC calibration system, the power and phase of each array element are measured in an RC. The relative power difference and phase shift are also calculated. The role of the mechanical stirrer is discussed. To verify the accuracy of the proposed method, we compare the calibration results with those obtained from the direct link method, and the measurement results are consistent. The proposed method validates the feasibility of PAA calibration in an RC, particularly when performing measurements of phase.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2024-11-13
DOI
https://doi.org/10.1109/tim.2024.3497161
Citations
1
Primary Topic
Electromagnetic Compatibility and Measurements
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibrating the Phased Array Antenna in a Reverberation Chamber

Wenjun Qi, Qian Xu, Yongjiu Zhao, Lei Xing et al.
1 citations
IEEE Transactions on Instrumentation and Measurement
Electromagnetic Compatibility and Measurements
0.21
article

Calibrating the Phased Array Antenna in a Reverberation Chamber

Wenjun Qi, Qian Xu, Yongjiu Zhao, Lei Xing, Feng Tian, Erwei Cheng, TIAN-SHUN FENG
article en
1 citations

Abstract

Identifying the power difference and phase shift of a phased array antenna (PAA) is essential in the PAA calibration. In this article, the ability of calibrating a PAA in a reverberation chamber (RC) is explored. Based on the proposed RC calibration system, the power and phase of each array element are measured in an RC. The relative power difference and phase shift are also calculated. The role of the mechanical stirrer is discussed. To verify the accuracy of the proposed method, we compare the calibration results with those obtained from the direct link method, and the measurement results are consistent. The proposed method validates the feasibility of PAA calibration in an RC, particularly when performing measurements of phase.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Jiangsu Institute of Metrology (CN), PLA Army Engineering University (CN), Nanjing University of Aeronautics and Astronautics (CN)
National Key Laboratory of Science and Technology on Communications, National Key Laboratory of Science and Technology on Micro/Nano Fabrication
Affordable and clean energy
Openalex Percentile: Top 46%
Electromagnetic Compatibility and Measurements
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Calibrating the Phased Array Antenna in a Reverberation Chamber — Wenjun Qi, Qian Xu, et al. · IEEE Transactions on Instrumentation and Measurement (2024) | TGRS Research Map | TGRS