The effect of the height difference between the two shoulders of the Kovar bracket on the rate of change of SLD full temperature power

In superluminescent diode (SLD), the height difference between the two shoulders of the kovar bracket (referred to as the shoulder difference) has a significant impact on the rate of change of SLD full temperature power (ΔP). To reduce the rate of change of SLD full temperature power, this paper verifies the influence of four sets of double shoulder differences at different heights on SLD full temperature power, and establishes a quantitative relationship between double shoulder differences and SLD full temperature power stability. The experimental results show that the shoulder difference is less than 10um, the mean Δ P is 1.86%, and the standard deviation is 0.008; the shoulder deviation is between 10um and 20um, with a mean Δ P of 2.88% and a standard deviation of 0.014. The shoulder deviation is between 20um and 40um, with a mean Δ P of 3.87% and a standard deviation of 0.016; the shoulder difference is greater than 40um, with a mean Δ P of 5.9% and a standard deviation of 0.040.

Authors

Publication Details

Published
2024-11-13
DOI
https://doi.org/10.1117/12.3047537
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The effect of the height difference between the two shoulders of the Kovar bracket on the rate of change of SLD full temperature power

Qiang Tang, Di Ma, Xing Chen, Qiaoning Duan et al.
Engineering Applied Research
article

The effect of the height difference between the two shoulders of the Kovar bracket on the rate of change of SLD full temperature power

Qiang Tang, Di Ma, Xing Chen, Qiaoning Duan, Jintao Xu, Miao Wang
article en

Abstract

In superluminescent diode (SLD), the height difference between the two shoulders of the kovar bracket (referred to as the shoulder difference) has a significant impact on the rate of change of SLD full temperature power (ΔP). To reduce the rate of change of SLD full temperature power, this paper verifies the influence of four sets of double shoulder differences at different heights on SLD full temperature power, and establishes a quantitative relationship between double shoulder differences and SLD full temperature power stability. The experimental results show that the shoulder difference is less than 10um, the mean Δ P is 1.86%, and the standard deviation is 0.008; the shoulder deviation is between 10um and 20um, with a mean Δ P of 2.88% and a standard deviation of 0.014. The shoulder deviation is between 20um and 40um, with a mean Δ P of 3.87% and a standard deviation of 0.016; the shoulder difference is greater than 40um, with a mean Δ P of 5.9% and a standard deviation of 0.040.

Affordable and clean energy
Openalex Percentile: Top 77%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The effect of the height difference between the two shoulders of the Kovar bracket on the rate of change of SLD full temperature power — Qiang Tang, Di Ma, et al. · (2024) | TGRS Research Map | TGRS