Porous and Homogeneous Nanoheterojunction-Accumulating PdO@ZnO Structure for Exhaled Breath Ammonia Sensing

The functional gas sensor device plays a pivotal role in intelligent medical treatment, among which metal oxide semiconductors are widely studied because of their inexpensiveness and ease of fabrication. However, the metal oxide sensors present a significant challenge in detecting NH<sub>3</sub> at ppm levels within complex exhaled gases. Herein, the ZnO/PdO-<i>x</i> series were prepared by in situ loading palladium particles and calcining using nano-ZIF-8 as a precursor, which not only provided more transport path for ammonia adsorption but also achieved homogeneous nanoheterojunction accumulation structure. The tailor-made ZnO/PdO-2 sensor exhibits the optimum gas sensitivity, with a response value of 5.56 for 100 ppm of NH<sub>3</sub> at 160 °C and a lower detection limit of 0.75 ppm. Particularly, it has a clear quantitative response to the actual exhaled gas of liver and kidney patients. By elucidating the intrinsic link between the in situ loading of MOF templates and the sensing mechanism, it is expected to broaden the rational design of metal-oxide sensors and thus provide an effective method for clinical detection.

Authors

Institutions

Publication Details

Journal
Inorganic Chemistry
Published
2024-11-13
DOI
https://doi.org/10.1021/acs.inorgchem.4c04094
Citations
5
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
1.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Porous and Homogeneous Nanoheterojunction-Accumulating PdO@ZnO Structure for Exhaled Breath Ammonia Sensing

Lifei Yin, Yang Chen, Yutao Liu, Jinping Li et al.
5 citations
Inorganic Chemistry
Gas Sensing Nanomaterials and Sensors
1.04
article

Porous and Homogeneous Nanoheterojunction-Accumulating PdO@ZnO Structure for Exhaled Breath Ammonia Sensing

Lifei Yin, Yang Chen, Yutao Liu, Jinping Li, Libo Li, Jia Yao, Zhengxuan Song, Yuxin Wang
article en
5 citations

Abstract

The functional gas sensor device plays a pivotal role in intelligent medical treatment, among which metal oxide semiconductors are widely studied because of their inexpensiveness and ease of fabrication. However, the metal oxide sensors present a significant challenge in detecting NH<sub>3</sub> at ppm levels within complex exhaled gases. Herein, the ZnO/PdO-<i>x</i> series were prepared by in situ loading palladium particles and calcining using nano-ZIF-8 as a precursor, which not only provided more transport path for ammonia adsorption but also achieved homogeneous nanoheterojunction accumulation structure. The tailor-made ZnO/PdO-2 sensor exhibits the optimum gas sensitivity, with a response value of 5.56 for 100 ppm of NH<sub>3</sub> at 160 °C and a lower detection limit of 0.75 ppm. Particularly, it has a clear quantitative response to the actual exhaled gas of liver and kidney patients. By elucidating the intrinsic link between the in situ loading of MOF templates and the sensing mechanism, it is expected to broaden the rational design of metal-oxide sensors and thus provide an effective method for clinical detection.

Inorganic ChemistryVol. 63(47)
Shanxi Medical University (CN), Shanxi Academy of Medical Sciences (CN), Taiyuan University of Technology (CN)
National Natural Science Foundation of China
Clean water and sanitation
Openalex Percentile: Top 22%
Gas Sensing Nanomaterials and Sensors
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.