Model-Based Parameter Selection for a Steerable Continuum Robot — Applications to Bronchoalveolar Lavage (BAL)

Bronchoalveolar lavage (BAL) is a minimally invasive procedure for diagnosing lung infections and diseases. However, navigating tortuous lung anatomy to the distal branches of the bronchoalveolar tree for adequate sampling using BAL remains challenging. Continuum robots have been used to improve the navigation of guidewires, catheters, and endoscopes and could be applied to the BAL procedure as well. One class of continuum robots is constructed from a notched tube and actuated using a tendon. Many tendon-driven notched continuum robots use uniform machining parameters to achieve approximately constant-curvature configurations, which may be unsuitable for traversing the tortuous anatomy of the lungs. This paper presents a model that predicts the curvature of a robot with arbitrary notch shapes subjected to tendon tension. The model predicted the deflection of rectangular, elliptical, and sinusoidal notches in a 0.89 mm diameter nitinol tube with 2.32%, 3.65%, and 6.32% error, respectively. Furthermore, an algorithm is developed to determine the optimal pattern of notches to achieve a desired nonuniform robot curvature. A simulated robot designed using the algorithm achieved the desired shape with a root mean square error (RMSE) of 1.52°. Additionally, we present a model for predicting the shape of nonuniformly notched continuum robots which incorporates friction and pre-curvature. This model predicted the shape of a continuum robot with nonuniform rectangular notches with an average RMSE of 5.20° with respect to the actual robot. We also demonstrated navigating the continuum robot through a pulmonary phantom.

Authors

Institutions

Publication Details

Journal
IEEE Robotics and Automation Letters
Published
2024-11-13
DOI
https://doi.org/10.1109/lra.2024.3497652
Citations
2
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Model-Based Parameter Selection for a Steerable Continuum Robot — Applications to Bronchoalveolar Lavage (BAL)

Revanth Konda, Kirsten M. Williams, Jaydev P. Desai, Timothy A. Brumfiel et al.
2 citations
IEEE Robotics and Automation Letters
Soft Robotics and Applications
0.37
article

Model-Based Parameter Selection for a Steerable Continuum Robot — Applications to Bronchoalveolar Lavage (BAL)

Revanth Konda, Kirsten M. Williams, Jaydev P. Desai, Timothy A. Brumfiel, Amber K. Rothe
article en
2 citations

Abstract

Bronchoalveolar lavage (BAL) is a minimally invasive procedure for diagnosing lung infections and diseases. However, navigating tortuous lung anatomy to the distal branches of the bronchoalveolar tree for adequate sampling using BAL remains challenging. Continuum robots have been used to improve the navigation of guidewires, catheters, and endoscopes and could be applied to the BAL procedure as well. One class of continuum robots is constructed from a notched tube and actuated using a tendon. Many tendon-driven notched continuum robots use uniform machining parameters to achieve approximately constant-curvature configurations, which may be unsuitable for traversing the tortuous anatomy of the lungs. This paper presents a model that predicts the curvature of a robot with arbitrary notch shapes subjected to tendon tension. The model predicted the deflection of rectangular, elliptical, and sinusoidal notches in a 0.89 mm diameter nitinol tube with 2.32%, 3.65%, and 6.32% error, respectively. Furthermore, an algorithm is developed to determine the optimal pattern of notches to achieve a desired nonuniform robot curvature. A simulated robot designed using the algorithm achieved the desired shape with a root mean square error (RMSE) of 1.52°. Additionally, we present a model for predicting the shape of nonuniformly notched continuum robots which incorporates friction and pre-curvature. This model predicted the shape of a continuum robot with nonuniform rectangular notches with an average RMSE of 5.20° with respect to the actual robot. We also demonstrated navigating the continuum robot through a pulmonary phantom.

IEEE Robotics and Automation LettersVol. 10(1)
Georgia Institute of Technology (US), Emory University (US), The Wallace H. Coulter Department of Biomedical Engineering (US), Children's Healthcare of Atlanta (US)
Emory University, National Institutes of Health, Winship Cancer Institute, National Heart, Lung, and Blood Institute
Climate action
Openalex Percentile: Top 42%
Soft Robotics and Applications
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.