Abstract A013: Quality control of the biobanked matched tissue: Blood samples for the development of diverse liquid based molecular assays

Abstract The availability of high-quality matched biological samples (tumor-blood) is the major limiting factor for research and development of novel, liquid biopsy-based assays in oncology. Frequently, ongoing specifically timed collections of blood samples are required. De-identified tissue blocks (formalin-fixed, paraffin embedded (FFPE) or flash frozen) matched with patient's blood samples collected in fixative-containing (Streck) of EDTA containing tubes, were collected at worldwide geographic locations and transferred to biobanking facility (Reference Medicine, Phoenix, AZ). Additional blood samples were collected at various times regarding the cancer surgery. Plasma and buffy coat samples were locally prepared and shipped to the biobank. A subset of blood samples without matched tissues from healthy donors were also collected. All samples were shipped under strict transport conditions. Quality control performed at the biobanking facility included pathology review and nucleic acids quality assessment. A total of over 3,000 cases were collected and provided to end-users working on various assays based on cfDNA (e.g. monitoring for minimal residual disease or multi-cancer early detection). Immuno-reactivity to various antigens in samples collected in Streck and EDTA tubes (from 50 patients) was assessed by peptide microarray binding assay. Feedback information on the quality of samples was shared in 900 cases. Approximately 4% of cases had failed internal pathology review, due to poor preservation, lack of adequate tissue composition, or low tumor volume and 11% failed internal nucleic acid quality assessment (DNA concetration and integrity). The blood collection tubes had no significant impact on serologic testing using peptide microarary assay. Customer feedback data showed that overall success rate exceeded 85%. Type of blood collection tubes (Streck vs EDTA) had no impact on serologic testing and studies looking at predicted neoantigens based on NGS data can be confirmed using peptide epitope arrays. Blood collected for NGS works without compromise on peptide arrays. Future validation of other collection tubes for blood or other types of fluids is needed to confirm their adequacy for specific assays. Citation Format: Zoran Gatalica, Phillip Stafford, Chris Diehnelt, Inga Rose. Quality control of the biobanked matched tissue: Blood samples for the development of diverse liquid based molecular assays [abstract]. In: Proceedings of the AACR Special Conference: Liquid Biopsy: From Discovery to Clinical Implementation; 2024 Nov 13-16; San Diego, CA. Philadelphia (PA): AACR; Clin Cancer Res 2024;30(21_Suppl):Abstract nr A013.

Authors

Institutions

Publication Details

Journal
Clinical Cancer Research
Published
2024-11-13
DOI
https://doi.org/10.1158/1557-3265.liqbiop24-a013
Primary Topic
Biosimilars and Bioanalytical Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract A013: Quality control of the biobanked matched tissue: Blood samples for the development of diverse liquid based molecular assays

Inga Rose, Chris W. Diehnelt, Zoran Gatalica, Phillip Stafford
Clinical Cancer Research
Biosimilars and Bioanalytical Methods
article

Abstract A013: Quality control of the biobanked matched tissue: Blood samples for the development of diverse liquid based molecular assays

Inga Rose, Chris W. Diehnelt, Zoran Gatalica, Phillip Stafford
article en

Abstract

Abstract The availability of high-quality matched biological samples (tumor-blood) is the major limiting factor for research and development of novel, liquid biopsy-based assays in oncology. Frequently, ongoing specifically timed collections of blood samples are required. De-identified tissue blocks (formalin-fixed, paraffin embedded (FFPE) or flash frozen) matched with patient's blood samples collected in fixative-containing (Streck) of EDTA containing tubes, were collected at worldwide geographic locations and transferred to biobanking facility (Reference Medicine, Phoenix, AZ). Additional blood samples were collected at various times regarding the cancer surgery. Plasma and buffy coat samples were locally prepared and shipped to the biobank. A subset of blood samples without matched tissues from healthy donors were also collected. All samples were shipped under strict transport conditions. Quality control performed at the biobanking facility included pathology review and nucleic acids quality assessment. A total of over 3,000 cases were collected and provided to end-users working on various assays based on cfDNA (e.g. monitoring for minimal residual disease or multi-cancer early detection). Immuno-reactivity to various antigens in samples collected in Streck and EDTA tubes (from 50 patients) was assessed by peptide microarray binding assay. Feedback information on the quality of samples was shared in 900 cases. Approximately 4% of cases had failed internal pathology review, due to poor preservation, lack of adequate tissue composition, or low tumor volume and 11% failed internal nucleic acid quality assessment (DNA concetration and integrity). The blood collection tubes had no significant impact on serologic testing using peptide microarary assay. Customer feedback data showed that overall success rate exceeded 85%. Type of blood collection tubes (Streck vs EDTA) had no impact on serologic testing and studies looking at predicted neoantigens based on NGS data can be confirmed using peptide epitope arrays. Blood collected for NGS works without compromise on peptide arrays. Future validation of other collection tubes for blood or other types of fluids is needed to confirm their adequacy for specific assays. Citation Format: Zoran Gatalica, Phillip Stafford, Chris Diehnelt, Inga Rose. Quality control of the biobanked matched tissue: Blood samples for the development of diverse liquid based molecular assays [abstract]. In: Proceedings of the AACR Special Conference: Liquid Biopsy: From Discovery to Clinical Implementation; 2024 Nov 13-16; San Diego, CA. Philadelphia (PA): AACR; Clin Cancer Res 2024;30(21_Suppl):Abstract nr A013.

Clinical Cancer ResearchVol. 30(21_Supplement)
Credo Reference (United States) (US)
Openalex Percentile: Top 74%
Biosimilars and Bioanalytical Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.