Beam emission spectroscopy diagnostic design and capabilities for two-dimensional turbulence measurements on Wendelstein 7-X

Abstract A beam emission spectroscopy (BES) diagnostic is designed for studying two-dimensional turbulent dynamics by measuring the Doppler-shifted Balmer-Alpha emission ( n = 3 → 2) from neutral heating beams on Wendelstein 7-X (W7-X) stellarator. The BES viewing geometry has been determined in the conceptual design previously. However, the small Doppler shifts and small optical throughput compared to a typical BES diagnostic demand dedicated efforts on the optical assemblies and the detector module for the BES system. We present the detailed opto-mechanical design and specifications of BES, including a customized neutral beam viewing optical system, a semi-telecentric optical assembly, and a detector module for electronic amplification. The point spread function is calculated using the pyFIDASIM code with experimental parameters and W7-X magnetic configurations to estimate the BES spatial resolution and beam intensity. The as-manufactured interference filter is applied for the spectral isolated beam radiance calculation. Result shows that the BES system is capable of measuring the ion-scale turbulence for k ⊥ ρ i ≤ 0.4 at r / a = 0.75 with reasonable spatial and wavenumber resolutions. An integrated detector module is fabricated where two 8×4 avalanche photodiode detectors (APD) are embedded into the custom-designed pre-amplifier circuit to gain signals to the desired level. The detector noise measurement is performed and the signal-to-noise ratio (SNR) is evaluated. A detectable fluctuation level can be achieved as low as ñ e / n e ≈ 0.5% at frequency f ≤ 400 kHz with a bandwidth of 1 MHz.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-11-01
DOI
https://doi.org/10.1088/1748-0221/19/11/p11004
Citations
1
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.66
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Beam emission spectroscopy diagnostic design and capabilities for two-dimensional turbulence measurements on Wendelstein 7-X

Daniel Den Hartog, Xiang Han, B. Geiger, O. Grulke et al.
1 citations
Journal of Instrumentation
Magnetic confinement fusion research
0.66
article

Beam emission spectroscopy diagnostic design and capabilities for two-dimensional turbulence measurements on Wendelstein 7-X

Daniel Den Hartog, Xiang Han, B. Geiger, O. Grulke, T. Windisch, K. Jaehnig, R. Laube, G. R. McKee, D. R. Smith, C. Seyfert, T. Gallenberger
article en
1 citations

Abstract

Abstract A beam emission spectroscopy (BES) diagnostic is designed for studying two-dimensional turbulent dynamics by measuring the Doppler-shifted Balmer-Alpha emission ( n = 3 → 2) from neutral heating beams on Wendelstein 7-X (W7-X) stellarator. The BES viewing geometry has been determined in the conceptual design previously. However, the small Doppler shifts and small optical throughput compared to a typical BES diagnostic demand dedicated efforts on the optical assemblies and the detector module for the BES system. We present the detailed opto-mechanical design and specifications of BES, including a customized neutral beam viewing optical system, a semi-telecentric optical assembly, and a detector module for electronic amplification. The point spread function is calculated using the pyFIDASIM code with experimental parameters and W7-X magnetic configurations to estimate the BES spatial resolution and beam intensity. The as-manufactured interference filter is applied for the spectral isolated beam radiance calculation. Result shows that the BES system is capable of measuring the ion-scale turbulence for k ⊥ ρ i ≤ 0.4 at r / a = 0.75 with reasonable spatial and wavenumber resolutions. An integrated detector module is fabricated where two 8×4 avalanche photodiode detectors (APD) are embedded into the custom-designed pre-amplifier circuit to gain signals to the desired level. The detector noise measurement is performed and the signal-to-noise ratio (SNR) is evaluated. A detectable fluctuation level can be achieved as low as ñ e / n e ≈ 0.5% at frequency f ≤ 400 kHz with a bandwidth of 1 MHz.

Journal of InstrumentationVol. 19(11)
Technical University of Denmark (DK)
Affordable and clean energy
Openalex Percentile: Top 14%
Magnetic confinement fusion research
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.