Abstract 4135928: Externally Validated Deep Learning Model for Patent Ductus Arteriosus Detection by Echocardiography in Preterm Infants

Introduction: Patent ductus arteriosus (PDA) is a common form of congenital heart disease in premature infants and a source of significant morbidity. Echocardiography is the mainstay modality for diagnosis and monitoring but is resource-intensive and requires expertise for interpretation. Aims: To develop and externally validate a deep learning model to identify PDA in preterm infants by echocardiography. Methods: We trained, validated, and tested a convolutional neural network to detect PDA in raw echocardiogram clips from infants (gestational age <37 weeks) with and without PDAs and no significant additional congenital heart disease at the Medical University of South Carolina (MUSC). For training and validation, we employed a 12-fold cross-validation procedure. Experienced cardiologists defined the ground truth labels. We assessed classification performance on an internal model naïve dataset using the area under the receiver operator curve (AUROC), sensitivity, specificity, positive predictive value, and negative predictive value. For external multicenter testing, we used studies from Children’s Hospital of Orange County (CHOC) and Boston Children’s Hospital (BCH), both of which utilize a different ultrasound system vendor. Results: Training and validation were completed using 1,145 color/color-compare clips (661 clips with PDA and 484 no PDA) from 66 patients. The internal test dataset consisted of 142 clips from 16 patients. The external CHOC and BCH cohorts consisted of 146 clips from 50 patients and 294 clips from 68 patients, respectively. Model performance was similar for internal and external testing (Table 1). Conclusions: Our deep learning model detected the presence of PDA with acceptable performance. This performance generalized well across multiple institutions and ultrasound vendors. This work shows promise for the future development of an automated tool for PDA diagnosis enabling the democratization of pediatric cardiology resources.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4135928
Citations
1
Primary Topic
Cardiovascular Conditions and Treatments
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4135928: Externally Validated Deep Learning Model for Patent Ductus Arteriosus Detection by Echocardiography in Preterm Infants

Wyman W. Lai, Gavin Baker, Addison Gearhart, Jason M. Graham et al.
1 citations
Circulation
Cardiovascular Conditions and Treatments
0.40
article

Abstract 4135928: Externally Validated Deep Learning Model for Patent Ductus Arteriosus Detection by Echocardiography in Preterm Infants

Wyman W. Lai, Gavin Baker, Addison Gearhart, Jason M. Graham, D. Hudson Smith, Christopher Baltimore, Thomas Gomes, Alexa Golbus, Andrew Powell, Micaela Elrod, Cayla Wakser
article en
1 citations

Abstract

Introduction: Patent ductus arteriosus (PDA) is a common form of congenital heart disease in premature infants and a source of significant morbidity. Echocardiography is the mainstay modality for diagnosis and monitoring but is resource-intensive and requires expertise for interpretation. Aims: To develop and externally validate a deep learning model to identify PDA in preterm infants by echocardiography. Methods: We trained, validated, and tested a convolutional neural network to detect PDA in raw echocardiogram clips from infants (gestational age <37 weeks) with and without PDAs and no significant additional congenital heart disease at the Medical University of South Carolina (MUSC). For training and validation, we employed a 12-fold cross-validation procedure. Experienced cardiologists defined the ground truth labels. We assessed classification performance on an internal model naïve dataset using the area under the receiver operator curve (AUROC), sensitivity, specificity, positive predictive value, and negative predictive value. For external multicenter testing, we used studies from Children’s Hospital of Orange County (CHOC) and Boston Children’s Hospital (BCH), both of which utilize a different ultrasound system vendor. Results: Training and validation were completed using 1,145 color/color-compare clips (661 clips with PDA and 484 no PDA) from 66 patients. The internal test dataset consisted of 142 clips from 16 patients. The external CHOC and BCH cohorts consisted of 146 clips from 50 patients and 294 clips from 68 patients, respectively. Model performance was similar for internal and external testing (Table 1). Conclusions: Our deep learning model detected the presence of PDA with acceptable performance. This performance generalized well across multiple institutions and ultrasound vendors. This work shows promise for the future development of an automated tool for PDA diagnosis enabling the democratization of pediatric cardiology resources.

CirculationVol. 150(Suppl_1)
Boston Children's Hospital (US), Children's Hospital of Orange County (US), Medical University of South Carolina (US), Clemson University (US)
Openalex Percentile: Top 33%
Cardiovascular Conditions and Treatments
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.