Abstract 4135353: Accuracy, Hallucinations, and Misgeneralizations of Large Language Models in Reviewing Cardiology Literature

Introduction: The text generation abilities of large language models (LLMs), such as ChatGPT, can streamline the process of research and potentially expedite reviewing literature. Methods: We evaluated the capabilities of LLMs and their major susceptibilities—hallucination and goal misgeneralization—in reviewing cardiology literature. We asked 30 comprehensive questions (n=600) regarding findings from notable cardiovascular studies and randomized controlled trials (n=20) from 2016-2020 to GPT-4, GPT-3.5, and LLaMa 3. The question groups followed a format where the initial question checked for accuracy in identification, second for misgeneralization, and third for hallucination (Table 1). All questions were communicated in individual interfaces of the models to retain independence and prevent bias. Responses were then reviewed for accuracy, misgeneralizations, and hallucinations. Results: GPT-4 and GPT-3.5 did not significantly differ in accuracy (55% vs. 40%, p=0.527), with a low association (φ=0.1) and an odds ratio (OR) of 1.83 (95% CI: 0.522-6.434). Similar results were observed between GPT-4 and LLaMa 3 (55% vs. 30%, p=0.201), with an OR of 2.85 (95% CI: 0.776-10.467). For generalization, GPT-4 and GPT-3.5 also did not significantly differ (30% vs. 35%, p=0.999), with a low association (φ=0.001) and an OR of 0.80 (95% CI: 0.211-2.998). Likewise, GPT-4 and LLaMa 3 showed no significant difference (30% vs. 25%, p=0.999), with an OR of 1.29 (95% CI: 0.319-5.174). For non-hallucinations, GPT-4 and GPT-3.5 did not significantly differ (30% vs. 60%, p=0.187), with a low association (φ=0.214) and an OR of 0.33 (95% CI: 0.088-1.256). Lastly, GPT-4 and LLaMa 3 showed no significant difference (30% vs. 25%, p=0.836), with an OR of 1.50 (95% CI: 0.36-6.13). Overall, all models did not differ in accuracy, misgeneralization, and hallucination. Given the moderate susceptibilities of these models, LLMs require more training before realistic usage in cardiology. Conclusions: LLMs show potential for identifying cardiology studies, but moderate hallucination and misgeneralization render them unsuitable for this purpose. Without resolution of susceptibilities (<5-10%), LLMs remain unrealistic for accurately reviewing literature.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4135353
Primary Topic
Machine Learning in Healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4135353: Accuracy, Hallucinations, and Misgeneralizations of Large Language Models in Reviewing Cardiology Literature

Joshua Pillai, Baharullah Mahin, Sarah Kim, Spencer Fang
Circulation
Machine Learning in Healthcare
article

Abstract 4135353: Accuracy, Hallucinations, and Misgeneralizations of Large Language Models in Reviewing Cardiology Literature

Joshua Pillai, Baharullah Mahin, Sarah Kim, Spencer Fang
article en

Abstract

Introduction: The text generation abilities of large language models (LLMs), such as ChatGPT, can streamline the process of research and potentially expedite reviewing literature. Methods: We evaluated the capabilities of LLMs and their major susceptibilities—hallucination and goal misgeneralization—in reviewing cardiology literature. We asked 30 comprehensive questions (n=600) regarding findings from notable cardiovascular studies and randomized controlled trials (n=20) from 2016-2020 to GPT-4, GPT-3.5, and LLaMa 3. The question groups followed a format where the initial question checked for accuracy in identification, second for misgeneralization, and third for hallucination (Table 1). All questions were communicated in individual interfaces of the models to retain independence and prevent bias. Responses were then reviewed for accuracy, misgeneralizations, and hallucinations. Results: GPT-4 and GPT-3.5 did not significantly differ in accuracy (55% vs. 40%, p=0.527), with a low association (φ=0.1) and an odds ratio (OR) of 1.83 (95% CI: 0.522-6.434). Similar results were observed between GPT-4 and LLaMa 3 (55% vs. 30%, p=0.201), with an OR of 2.85 (95% CI: 0.776-10.467). For generalization, GPT-4 and GPT-3.5 also did not significantly differ (30% vs. 35%, p=0.999), with a low association (φ=0.001) and an OR of 0.80 (95% CI: 0.211-2.998). Likewise, GPT-4 and LLaMa 3 showed no significant difference (30% vs. 25%, p=0.999), with an OR of 1.29 (95% CI: 0.319-5.174). For non-hallucinations, GPT-4 and GPT-3.5 did not significantly differ (30% vs. 60%, p=0.187), with a low association (φ=0.214) and an OR of 0.33 (95% CI: 0.088-1.256). Lastly, GPT-4 and LLaMa 3 showed no significant difference (30% vs. 25%, p=0.836), with an OR of 1.50 (95% CI: 0.36-6.13). Overall, all models did not differ in accuracy, misgeneralization, and hallucination. Given the moderate susceptibilities of these models, LLMs require more training before realistic usage in cardiology. Conclusions: LLMs show potential for identifying cardiology studies, but moderate hallucination and misgeneralization render them unsuitable for this purpose. Without resolution of susceptibilities (<5-10%), LLMs remain unrealistic for accurately reviewing literature.

CirculationVol. 150(Suppl_1)
Harvard University Press (US), University of California San Diego (US), Case Western Reserve University (US)
Quality Education
Openalex Percentile: Top 82%
Machine Learning in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.