High cycle performance of twisted and coiled polymer actuators

Twisted and coiled polymer actuators (TCPA), also known as coiled artificial muscles, are gaining popularity in soft robotics due to their large contractile actuation and work capacity. However, while it has been previously claimed that the stroke of TCPA remains stable after thousands of cycles, their absolute length change has not been rigorously studied. Here, we constructed an isobaric cycling setup that relies on fast heating and cooling by water immersion. This enables testing for 10k cycles in a duration of 56 hours, where the muscle temperature is varied between 15 °C and 75 °C at a rate of 20 seconds per cycle. Surprisingly, while the stroke usually remains unchanged for the entire 10k cycles as previously claimed, the final muscle loaded length exhibits all the geometrical possibilities of creep behavior as it can remain unchanged, elongate (creep), or contract (reverse creep) at the end of the test. Based on a wide range of experiments, we derived an empirical law which captures the observed relationship between the final muscle length change Δ L , the stroke α , and the passive strain ε 0 : ε 0 + α = Δ L . Using this relation, the final length change of the muscle can be predicted from the first 100 cycles only. We show that polyvinylidene fluoride (PVDF), which does not swell in water, and nylon, which swells, follow this empirical law by testing in water with and without a protective coating, respectively. These results offer practical design guidelines for predictive actuation over thousands of cycles. • The high cycle life of twisted and coiled polymer actuators is characterized by the stroke change and the final length. • We built a liquid isobaric cycling setup to investigate twisted and coiled polymer actuators for 10k cycles. • While the stroke remains constant, the muscle length elongates (creep), contracts (reverse creep), or remains unchanged. • We derived an empirical relation for the muscle length by the stroke-strain difference observed in the first 100 cycles.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators A Physical
Published
2024-11-13
DOI
https://doi.org/10.1016/j.sna.2024.116041
Citations
10
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
1.84

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High cycle performance of twisted and coiled polymer actuators

Sameh Tawfick, William P. King, Qiong Wang, Oh-Nyoung Hur et al.
10 citations
Sensors and Actuators A Physical
Advanced Sensor and Energy Harvesting Materials
1.84
article

High cycle performance of twisted and coiled polymer actuators

Sameh Tawfick, William P. King, Qiong Wang, Oh-Nyoung Hur, Michael D. Bartlett, S. W. Tsai
article en
10 citations

Abstract

Twisted and coiled polymer actuators (TCPA), also known as coiled artificial muscles, are gaining popularity in soft robotics due to their large contractile actuation and work capacity. However, while it has been previously claimed that the stroke of TCPA remains stable after thousands of cycles, their absolute length change has not been rigorously studied. Here, we constructed an isobaric cycling setup that relies on fast heating and cooling by water immersion. This enables testing for 10k cycles in a duration of 56 hours, where the muscle temperature is varied between 15 °C and 75 °C at a rate of 20 seconds per cycle. Surprisingly, while the stroke usually remains unchanged for the entire 10k cycles as previously claimed, the final muscle loaded length exhibits all the geometrical possibilities of creep behavior as it can remain unchanged, elongate (creep), or contract (reverse creep) at the end of the test. Based on a wide range of experiments, we derived an empirical law which captures the observed relationship between the final muscle length change Δ L , the stroke α , and the passive strain ε 0 : ε 0 + α = Δ L . Using this relation, the final length change of the muscle can be predicted from the first 100 cycles only. We show that polyvinylidene fluoride (PVDF), which does not swell in water, and nylon, which swells, follow this empirical law by testing in water with and without a protective coating, respectively. These results offer practical design guidelines for predictive actuation over thousands of cycles. • The high cycle life of twisted and coiled polymer actuators is characterized by the stroke change and the final length. • We built a liquid isobaric cycling setup to investigate twisted and coiled polymer actuators for 10k cycles. • While the stroke remains constant, the muscle length elongates (creep), contracts (reverse creep), or remains unchanged. • We derived an empirical relation for the muscle length by the stroke-strain difference observed in the first 100 cycles.

Sensors and Actuators A PhysicalVol. 381
University of Illinois Urbana-Champaign (US), Virginia Tech (US)
National Science Foundation, Toyota Research Institute, Office of Naval Research, Division of Civil, Mechanical and Manufacturing Innovation
Affordable and clean energy
Openalex Percentile: Top 15%
Advanced Sensor and Energy Harvesting Materials
1.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.