Bio-inspired PDMS microcantilever flow meter

Flow rate is one of the most important parameters used in various applications, including biomedical engineering and industrial applications. PDMS has been considered a biocompatible material for making flow sensors. Measuring low flows is one of the upcoming challenges in using this type of flowmeter. This study aims to examine the potential of PDMS microcantilevers to measure the low flow rates in microfluidic networks for biological applications. For this purpose, this study attempts to increase the sensitivity and accuracy of a PDMS microcantilever-based flow meter. The effect of the microcantilever’s shape on the device’s sensitivity is investigated. The fluid interaction with the PDMS structure is studied using the finite element method (FEM) to measure the beam's deformation. Results indicate that the best shape for the cantilever in the flow meter to have the highest accuracy and sensitivity is the bio-mimic model inspired by octopus arms. The sensitivity and accuracy of the flow sensor using this model increased by 157% and 53.8% compared to those in previous models, respectively.

Authors

Institutions

Publication Details

Journal
Discover Mechanical Engineering
Published
2024-11-12
DOI
https://doi.org/10.1007/s44245-024-00077-0
Citations
1
Primary Topic
Mechanical and Optical Resonators
Type
article
Field-Weighted Citation Impact
0.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bio-inspired PDMS microcantilever flow meter

Naser Naserifar, Ahmad Naseri Karimvand, Shayan Rahimi Shahmirzadi
1 citations
Discover Mechanical Engineering
Mechanical and Optical Resonators
0.34
article

Bio-inspired PDMS microcantilever flow meter

Naser Naserifar, Ahmad Naseri Karimvand, Shayan Rahimi Shahmirzadi
article en
1 citations

Abstract

Flow rate is one of the most important parameters used in various applications, including biomedical engineering and industrial applications. PDMS has been considered a biocompatible material for making flow sensors. Measuring low flows is one of the upcoming challenges in using this type of flowmeter. This study aims to examine the potential of PDMS microcantilevers to measure the low flow rates in microfluidic networks for biological applications. For this purpose, this study attempts to increase the sensitivity and accuracy of a PDMS microcantilever-based flow meter. The effect of the microcantilever’s shape on the device’s sensitivity is investigated. The fluid interaction with the PDMS structure is studied using the finite element method (FEM) to measure the beam's deformation. Results indicate that the best shape for the cantilever in the flow meter to have the highest accuracy and sensitivity is the bio-mimic model inspired by octopus arms. The sensitivity and accuracy of the flow sensor using this model increased by 157% and 53.8% compared to those in previous models, respectively.

Discover Mechanical EngineeringVol. 3(1)
University of Utah (US), K. N. Toosi University of Technology (IR)
Openalex Percentile: Top 39%
Mechanical and Optical Resonators
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.