Selenium Hydride-Induced Oxidase-like Activity Inhibition of Amorphous/Crystalline Manganese Dioxide: Colorimetric Assay for Selenium Detection

Hydride generation-based optical sensors have achieved on-site visual selenium (Se) determination with high anti-interference capability, yet they rely on the change of single-color intensity with a narrow linear dynamic range. Herein, we combined selenium hydride (H<sub>2</sub>Se)-induced activity inhibition of a manganese dioxide (MnO<sub>2</sub>) nanozyme with different degrees of 3,3',5,5'-tetramethylbenzidine (TMB) oxidation to realize sensitive multicolor visual detection of Se(IV). Due to its high oxidase-like (OXD-like) activity and sensitive response to H<sub>2</sub>Se, amorphous/crystalline manganese dioxide (<i>ac</i>-MnO<sub>2</sub>) was selected to form the headspace single droplet for microextraction and recognition. <i>Via</i> headspace redox reaction with H<sub>2</sub>Se, <i>ac</i>-MnO<sub>2</sub> was reduced into low valence accompanied by in situ generation of Se nanoparticles, leading to the formation of a Se-MnO<sub><i>x</i></sub> aggregate. The experimental results and theoretical calculation indicated that, compared with MnO<sub>2</sub>, Se-MnO<sub><i>x</i></sub> had decreased active sites for adsorbing O<sub>2</sub> to generate <sup>•</sup>O<sub>2</sub><sup>-</sup>, resulting in the nanozyme activity inhibition that was totally dependent on Se(IV) concentration. The implementation of this strategy enabled accurate Se(IV) detection with a linear range from 10 to 600 μg L<sup>-1</sup> and a limit of detection of 1.8 μg L<sup>-1</sup>. The portable smartphone-based detection for real sample analysis further demonstrated that this assay can be an easy, convenient, and intelligent tool for on-site selenium determination.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-11-12
DOI
https://doi.org/10.1021/acs.analchem.4c03738
Citations
17
Primary Topic
Advanced Nanomaterials in Catalysis
Type
article
Field-Weighted Citation Impact
1.99

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Selenium Hydride-Induced Oxidase-like Activity Inhibition of Amorphous/Crystalline Manganese Dioxide: Colorimetric Assay for Selenium Detection

B. Wang, Xiandeng Hou, Qing Xiong, Ma B et al.
17 citations
Analytical Chemistry
Advanced Nanomaterials in Catalysis
1.99
article

Selenium Hydride-Induced Oxidase-like Activity Inhibition of Amorphous/Crystalline Manganese Dioxide: Colorimetric Assay for Selenium Detection

B. Wang, Xiandeng Hou, Qing Xiong, Ma B, Xiaoping Zou, Kailai Xu, Shan Pu
article en
17 citations

Abstract

Hydride generation-based optical sensors have achieved on-site visual selenium (Se) determination with high anti-interference capability, yet they rely on the change of single-color intensity with a narrow linear dynamic range. Herein, we combined selenium hydride (H<sub>2</sub>Se)-induced activity inhibition of a manganese dioxide (MnO<sub>2</sub>) nanozyme with different degrees of 3,3',5,5'-tetramethylbenzidine (TMB) oxidation to realize sensitive multicolor visual detection of Se(IV). Due to its high oxidase-like (OXD-like) activity and sensitive response to H<sub>2</sub>Se, amorphous/crystalline manganese dioxide (<i>ac</i>-MnO<sub>2</sub>) was selected to form the headspace single droplet for microextraction and recognition. <i>Via</i> headspace redox reaction with H<sub>2</sub>Se, <i>ac</i>-MnO<sub>2</sub> was reduced into low valence accompanied by in situ generation of Se nanoparticles, leading to the formation of a Se-MnO<sub><i>x</i></sub> aggregate. The experimental results and theoretical calculation indicated that, compared with MnO<sub>2</sub>, Se-MnO<sub><i>x</i></sub> had decreased active sites for adsorbing O<sub>2</sub> to generate <sup>•</sup>O<sub>2</sub><sup>-</sup>, resulting in the nanozyme activity inhibition that was totally dependent on Se(IV) concentration. The implementation of this strategy enabled accurate Se(IV) detection with a linear range from 10 to 600 μg L<sup>-1</sup> and a limit of detection of 1.8 μg L<sup>-1</sup>. The portable smartphone-based detection for real sample analysis further demonstrated that this assay can be an easy, convenient, and intelligent tool for on-site selenium determination.

Analytical ChemistryVol. 96(47)
Sichuan University (CN)
National Natural Science Foundation of China, Higher Education Discipline Innovation Project, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 9%
Advanced Nanomaterials in Catalysis
1.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.