Enhancing energy efficiency in shipping container house: A novel approach using hybrid louver systems

• Optimized surrounding shades can improve energy savings and visual comfort. • Prefabricated buildings are specifically suitable for warm climate zones. • Proposed hybrid shadings achieved a higher reduction in energy consumption. • The hybrid louvers can replace horizontal, vertical, and egg-crate shadings. Reusing shipping containers for residential purposes offers a promising approach to address global energy consumption challenges from economic and environmental perspectives. This study parametrically designed hybrid louver shadings by combining fixed vertical triangular slats with variable-depth horizontal rectangular slats, offering a novel approach to shading prefabricated buildings. The energy consumption, daylighting performance, and visual comfort were assessed for various shading configurations. Results indicated that implementing the proposed hybrid louvers, featuring fixed vertical triangular slats and variable-depth horizontal rectangular slats, significantly reduced Energy Use Intensity (EUI) to 133.95 kWh/m 2 . Moreover, Useful daylight illuminance (UDI), Daylight Autonomy (DA), and Glare Autonomy (GA) values improved to 95.38%, 89.97%, and 91.16%, respectively. The study highlighted the potential of the proposed shading system to significantly reduce overall energy consumption across various ASHRAE climate zones, including Miami (1A), Guangzhou (2A), Melbourne (3C), Esperance (3C), San Diego (3A), and Milan (4A). Notably, energy reductions of up to 50.2% were projected for climates such as Miami (1A) and San Diego (3A). Furthermore, container buildings in warm climate zones exhibited a significantly lower EUI range of 76.58 to 91.95 kWh/m². This study underscores the transformative potential of hybrid louver systems in promoting the widespread adoption of sustainable residential architecture, contributing to global sustainability efforts.

Authors

Institutions

Publication Details

Journal
Energy and Built Environment
Published
2024-11-12
DOI
https://doi.org/10.1016/j.enbenv.2024.11.003
Citations
7
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
1.86

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing energy efficiency in shipping container house: A novel approach using hybrid louver systems

Muna Alsukkar, Mao-Bin Hu, Yifang Dong, Amir Hamza et al.
7 citations
Energy and Built Environment
Building Energy and Comfort Optimization
1.86
article

Enhancing energy efficiency in shipping container house: A novel approach using hybrid louver systems

Muna Alsukkar, Mao-Bin Hu, Yifang Dong, Amir Hamza, Adnan Ibrahim, Farrukh Saleem, Peng Hu
article en
7 citations

Abstract

• Optimized surrounding shades can improve energy savings and visual comfort. • Prefabricated buildings are specifically suitable for warm climate zones. • Proposed hybrid shadings achieved a higher reduction in energy consumption. • The hybrid louvers can replace horizontal, vertical, and egg-crate shadings. Reusing shipping containers for residential purposes offers a promising approach to address global energy consumption challenges from economic and environmental perspectives. This study parametrically designed hybrid louver shadings by combining fixed vertical triangular slats with variable-depth horizontal rectangular slats, offering a novel approach to shading prefabricated buildings. The energy consumption, daylighting performance, and visual comfort were assessed for various shading configurations. Results indicated that implementing the proposed hybrid louvers, featuring fixed vertical triangular slats and variable-depth horizontal rectangular slats, significantly reduced Energy Use Intensity (EUI) to 133.95 kWh/m 2 . Moreover, Useful daylight illuminance (UDI), Daylight Autonomy (DA), and Glare Autonomy (GA) values improved to 95.38%, 89.97%, and 91.16%, respectively. The study highlighted the potential of the proposed shading system to significantly reduce overall energy consumption across various ASHRAE climate zones, including Miami (1A), Guangzhou (2A), Melbourne (3C), Esperance (3C), San Diego (3A), and Milan (4A). Notably, energy reductions of up to 50.2% were projected for climates such as Miami (1A) and San Diego (3A). Furthermore, container buildings in warm climate zones exhibited a significantly lower EUI range of 76.58 to 91.95 kWh/m². This study underscores the transformative potential of hybrid louver systems in promoting the widespread adoption of sustainable residential architecture, contributing to global sustainability efforts.

Energy and Built EnvironmentVol. 7(2)
University of Science and Technology of China (CN), Hashemite University (JO), Chinese Academy of Sciences (CN), Institute of Microelectronics (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 15%
Building Energy and Comfort Optimization
1.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.