Investigation of the arrangement of aluminum fins on the thermal behavior of lauric acid as a phase change material in a two-pipe heat exchanger by CFD simulation

Phase change material (PCM) thermal storage systems store more thermal energy per unit volume than sensible heat storage systems. PCMs offer a potential solution to reduce energy consumption in various thermal engineering applications. This study aimed to examine how fin arrangement affected the thermal efficiency and melting time of PCMs. A two-dimensional numerical analysis of the melting process of lauric acid in a heat exchanger featuring two pipelines and fins was conducted using CFD simulation. In most previous investigations, the heat transfer fluid was a single-phase liquid. An enthalpy-porosity technique was used to model the solid and liquid phases of PCM. The governing equations were solved using the commercial software ANSYS Fluent 2021, and the pressure and velocity equations were coupled using the SIMPLE algorithm. The best model among the 13 tested was Model 5, which featured 6 fins and a consistent angle of 60°. For Model 5, the melting time was 1818.3 s. Due to sensible heating, the fin's temperature (Temp) rose gradually from 300 K to 318 K. Temp then gradually increased as the PCM melted in the phase transition zone between 316.5 K and 321.2 K. Once the phase transition was complete, the PCM's Temp steadily rose from 324 K to 340 K. In Model 5, the inner wall Temp and the maximum Temp of the PCM were closest, at 327.34 K and 333.55 K, respectively. The thermal shock between the PCM and the ambient Temp caused a peak heat flux at the beginning of the PCM loading process.

Authors

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2024-11-12
DOI
https://doi.org/10.1016/j.csite.2024.105469
Citations
9
Primary Topic
Phase Change Materials Research
Type
article
Field-Weighted Citation Impact
1.91
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the arrangement of aluminum fins on the thermal behavior of lauric acid as a phase change material in a two-pipe heat exchanger by CFD simulation

Pardeep Singh Bains, Maboud Hekmatifar, Muntadher Abed Hussein, Anjan Kumar et al.
9 citations
Case Studies in Thermal Engineering
Phase Change Materials Research
1.91
article

Investigation of the arrangement of aluminum fins on the thermal behavior of lauric acid as a phase change material in a two-pipe heat exchanger by CFD simulation

Pardeep Singh Bains, Maboud Hekmatifar, Muntadher Abed Hussein, Anjan Kumar, Talib M. Albayati, Soheil Salahshour, Weidong Liu, Majid Mokhtari, Hadeel Kareem Abdul-Redha
article en
9 citations

Abstract

Phase change material (PCM) thermal storage systems store more thermal energy per unit volume than sensible heat storage systems. PCMs offer a potential solution to reduce energy consumption in various thermal engineering applications. This study aimed to examine how fin arrangement affected the thermal efficiency and melting time of PCMs. A two-dimensional numerical analysis of the melting process of lauric acid in a heat exchanger featuring two pipelines and fins was conducted using CFD simulation. In most previous investigations, the heat transfer fluid was a single-phase liquid. An enthalpy-porosity technique was used to model the solid and liquid phases of PCM. The governing equations were solved using the commercial software ANSYS Fluent 2021, and the pressure and velocity equations were coupled using the SIMPLE algorithm. The best model among the 13 tested was Model 5, which featured 6 fins and a consistent angle of 60°. For Model 5, the melting time was 1818.3 s. Due to sensible heating, the fin's temperature (Temp) rose gradually from 300 K to 318 K. Temp then gradually increased as the PCM melted in the phase transition zone between 316.5 K and 321.2 K. Once the phase transition was complete, the PCM's Temp steadily rose from 324 K to 340 K. In Model 5, the inner wall Temp and the maximum Temp of the PCM were closest, at 327.34 K and 333.55 K, respectively. The thermal shock between the PCM and the ambient Temp caused a peak heat flux at the beginning of the PCM loading process.

Case Studies in Thermal EngineeringVol. 64
Openalex Percentile: Top 15%
Phase Change Materials Research
1.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.