Verification of a System for Calibrating Optical Transmission Path Asymmetry

This work addresses the calibration of asymmetry in optical transmission paths for precise time and frequency distribution. Specifically, we focus on calibrating White Rabbit technology, where local calibration is not possible due to the considerable distance between synchronized nodes. We developed an automatic calibration system using micro-electromechanical optical switches, which we verified under laboratory conditions. The verification process utilizes a basic calibration method, employing an auxiliary communication channel to transmit the 1PPS signal from a remote synchronized White Rabbit node for local comparison. The remote 1PPS signal’s transmission direction is time-multiplexed. Experimental results from a laboratory model of a real optical transmission system demonstrated the alignment between the automatic calibration system and our verification chain. The change in optical system asymmetry, simulated by adding additional optical fiber to the existing path, resulted in measured asymmetry changes of 101.5 ps by the automatic system and 102.6 ps by the verification chain. The overall difference between these two calibration methods was 1.1 ps. These findings confirm that the automatic system provides reliable results for calibrating asymmetry in optical transmission systems.

Authors

Institutions

Publication Details

Published
2024-10-07
DOI
https://doi.org/10.1109/ispcs63021.2024.10747716
Primary Topic
Semiconductor Lasers and Optical Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Verification of a System for Calibrating Optical Transmission Path Asymmetry

Jaroslav Roztočil, Josef Vojtěch, Michal Špaček
Semiconductor Lasers and Optical Devices
article

Verification of a System for Calibrating Optical Transmission Path Asymmetry

Jaroslav Roztočil, Josef Vojtěch, Michal Špaček
article en

Abstract

This work addresses the calibration of asymmetry in optical transmission paths for precise time and frequency distribution. Specifically, we focus on calibrating White Rabbit technology, where local calibration is not possible due to the considerable distance between synchronized nodes. We developed an automatic calibration system using micro-electromechanical optical switches, which we verified under laboratory conditions. The verification process utilizes a basic calibration method, employing an auxiliary communication channel to transmit the 1PPS signal from a remote synchronized White Rabbit node for local comparison. The remote 1PPS signal’s transmission direction is time-multiplexed. Experimental results from a laboratory model of a real optical transmission system demonstrated the alignment between the automatic calibration system and our verification chain. The change in optical system asymmetry, simulated by adding additional optical fiber to the existing path, resulted in measured asymmetry changes of 101.5 ps by the automatic system and 102.6 ps by the verification chain. The overall difference between these two calibration methods was 1.1 ps. These findings confirm that the automatic system provides reliable results for calibrating asymmetry in optical transmission systems.

Czech Technical University in Prague (CZ), CESNET, zájmové sdružení právnických osob (CZ)
Openalex Percentile: Top 82%
Semiconductor Lasers and Optical Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Verification of a System for Calibrating Optical Transmission Path Asymmetry — Jaroslav Roztočil, Josef Vojtěch, et al. · (2024) | TGRS Research Map | TGRS