OPTIMASI DAN VALIDASI METODE KLT-DENSITOMETRI FASE TERBALIK UNTUK ANALISIS OKSIBENZON DALAM LOSION TABIR SURYA

AbstractSunscreen is useful for protecting the skin against sun exposure. Oxybenzone is one of the active ingredients in sunscreen which can cause skin allergies, redness, dryness, and acne. This study aims to optimize and validate the reverse phase densitometry thin layer chromatography (TLC) method for the analysis of oxybenzone in sunscreen lotions. The TLC silica gel 60 RP-18 F254 was used as the stationary phase, the mobile phase was acetonitrile: aquabidest (18:3). The Rf values of oxybenzone in lotion A and B were 0.63. The resolution of oxybenzone in lotions A and B were 2.53 and 3.2, respectively. The correlation coefficient (r) of oxybenzone was 0.999 in the range of 50 – 250 μg/mL, the limit of detection was 16.37 μg/mL and the limit of quantitation was 49.39 μg/mL. The precision of lotions A and B was ≤ 2%. The % recovery of oxybenzone in lotion A and lotion B was 99.33-99.63%. The results showed that the levels of oxybenzone lotion A and B were 3.4% and 2.59% successively. The reverse phase TLC-Densitometry method is a valid method for the analysis of oxybenzone in sunscreen lotions.Keywords: Oxybenzone, sunscreen, validation, thin layer chromatography-densitometry, reversed-phase. OPTIMASI DAN VALIDASI METODE KLT-DENSITOMETRI FASE TERBALIK UNTUK ANALISIS OKSIBENZON DALAM LOSION TABIR SURYA Abstrak Tabir surya berguna untuk melindungi kulit dari paparan sinar matahari. Oxybenzone merupakan salah satu bahan aktif tabir surya yang dapat menyebabkan alergi kulit, kemerahan, kering dan berjerawat. Penelitian ini bertujuan untuk mengoptimalkan dan memvalidasi metode kromatografi lapis tipis (KLT) densitometri fase terbalik untuk analisis oksibenzon dalam lotion tabir surya. Silika gel TLC 60 RP-18 F254 digunakan sebagai fase diam, fase geraknya adalah asetonitril: akuabides (18:3). Nilai Rf oxybenzone pada lotion A dan B adalah 0,63. Resolusi oxybenzone pada lotion A dan B berturut-turut adalah 2,53 dan 3,2. Koefisien korelasi (r) oxybenzone adalah 0,999 dalam kisaran 50 – 250 μg/mL, batas deteksi adalah 16,37 μg/mL dan batas kuantitasi adalah 49,39 μg/mL. Nilai presisis lotion A dan lotion B adalah ≤ 2%. Persentase perolehan kembali oxybenzone pada lotion A dan lotion B adalah 99,33-99,63%. Hasil penelitian menunjukkan bahwa kadar oxybenzone lotion A dan B berturut-turut adalah 3,4% dan 2,59%. Metode TLC-Densitometry fase terbalik adalah metode yang valid untuk analisis oxybenzone dalam lotion tabir surya.Kata kunci: Oxybenzone, tabir surya, validasi, kromatografi lapis tipis-densitometri, fase terbalik.

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Pharmaceutical Science and Technology
Published
2024-11-06
DOI
https://doi.org/10.24198/ijpst.v11i3.43555
Primary Topic
Natural Products and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

OPTIMASI DAN VALIDASI METODE KLT-DENSITOMETRI FASE TERBALIK UNTUK ANALISIS OKSIBENZON DALAM LOSION TABIR SURYA

Fithriani Armin, Regina Andayani, Retno Permata Andira
Indonesian Journal of Pharmaceutical Science and Technology
Natural Products and Applications
article

OPTIMASI DAN VALIDASI METODE KLT-DENSITOMETRI FASE TERBALIK UNTUK ANALISIS OKSIBENZON DALAM LOSION TABIR SURYA

Fithriani Armin, Regina Andayani, Retno Permata Andira
article en

Abstract

AbstractSunscreen is useful for protecting the skin against sun exposure. Oxybenzone is one of the active ingredients in sunscreen which can cause skin allergies, redness, dryness, and acne. This study aims to optimize and validate the reverse phase densitometry thin layer chromatography (TLC) method for the analysis of oxybenzone in sunscreen lotions. The TLC silica gel 60 RP-18 F254 was used as the stationary phase, the mobile phase was acetonitrile: aquabidest (18:3). The Rf values of oxybenzone in lotion A and B were 0.63. The resolution of oxybenzone in lotions A and B were 2.53 and 3.2, respectively. The correlation coefficient (r) of oxybenzone was 0.999 in the range of 50 – 250 μg/mL, the limit of detection was 16.37 μg/mL and the limit of quantitation was 49.39 μg/mL. The precision of lotions A and B was ≤ 2%. The % recovery of oxybenzone in lotion A and lotion B was 99.33-99.63%. The results showed that the levels of oxybenzone lotion A and B were 3.4% and 2.59% successively. The reverse phase TLC-Densitometry method is a valid method for the analysis of oxybenzone in sunscreen lotions.Keywords: Oxybenzone, sunscreen, validation, thin layer chromatography-densitometry, reversed-phase. OPTIMASI DAN VALIDASI METODE KLT-DENSITOMETRI FASE TERBALIK UNTUK ANALISIS OKSIBENZON DALAM LOSION TABIR SURYA Abstrak Tabir surya berguna untuk melindungi kulit dari paparan sinar matahari. Oxybenzone merupakan salah satu bahan aktif tabir surya yang dapat menyebabkan alergi kulit, kemerahan, kering dan berjerawat. Penelitian ini bertujuan untuk mengoptimalkan dan memvalidasi metode kromatografi lapis tipis (KLT) densitometri fase terbalik untuk analisis oksibenzon dalam lotion tabir surya. Silika gel TLC 60 RP-18 F254 digunakan sebagai fase diam, fase geraknya adalah asetonitril: akuabides (18:3). Nilai Rf oxybenzone pada lotion A dan B adalah 0,63. Resolusi oxybenzone pada lotion A dan B berturut-turut adalah 2,53 dan 3,2. Koefisien korelasi (r) oxybenzone adalah 0,999 dalam kisaran 50 – 250 μg/mL, batas deteksi adalah 16,37 μg/mL dan batas kuantitasi adalah 49,39 μg/mL. Nilai presisis lotion A dan lotion B adalah ≤ 2%. Persentase perolehan kembali oxybenzone pada lotion A dan lotion B adalah 99,33-99,63%. Hasil penelitian menunjukkan bahwa kadar oxybenzone lotion A dan B berturut-turut adalah 3,4% dan 2,59%. Metode TLC-Densitometry fase terbalik adalah metode yang valid untuk analisis oxybenzone dalam lotion tabir surya.Kata kunci: Oxybenzone, tabir surya, validasi, kromatografi lapis tipis-densitometri, fase terbalik.

Indonesian Journal of Pharmaceutical Science and TechnologyVol. 11(3)
Andalas University (ID)
Openalex Percentile: Top 64%
Natural Products and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.