Evaluation of the Heat Transfer Performance of a Device Utilizing an Asymmetric Pulsating Heat Pipe Structure Based on Global and Local Analysis

PHPs (pulsating heat pipes) are widely used as an efficient heat transfer element in equipment thermal management and waste heat recovery due to their flexibility. The purpose of this study was to design a heat transfer device that utilizes an asymmetric pulsating heat pipe structure by adjusting the lengths of selected pipes within the entire circulation pipeline. In the experiment, a constant temperature water bath was used as the heat source, with heat dissipated in the condensing section via natural convection. An infrared thermal imager was used to record the temperature of the condensing section, and the local wall temperature distribution was measured in different channels of the condensing section. Based on an in-depth analysis of the wavelet frequency, the following research conclusions are drawn: Firstly, as the heat source temperature increases, the start-up time of the pulsating heat pipe is shortened, the operating state changes from start–stop–start to stable and continuous oscillation, and the oscillation mode changes from high amplitude and low frequency to low amplitude and high frequency. These changes are especially pronounced when the heat source temperature is 80 °C, which is when the thermal resistance reaches its lowest value of 0.0074 K/W, and the equivalent thermal conductivity reaches its highest value of 666.29 W/(m·K). Secondly, the flow and oscillation of the working fluid can be effectively promoted by appropriately shortening the length of the condensing section of the pulsating heat pipes or the heat transfer distance between the evaporation and condensing sections. Third, under a low-temperature heat source, the oscillation frequency of each channel of a pulsating heat pipe is found to be low based on wavelet analysis. However, as the heat source temperature increases, the energy content of the temperature signal of the working fluid in each channel changes from a low- to a high-frequency value, gradually converging to the same characteristic frequency. At this point, the working fluid in the pipes no longer flows randomly in multiple directions but rather in a single direction. Finally, we determined that the maximum oscillation frequency of working fluid in a PHP is around 0.7 HZ when using the water bath heating method.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-11-08
DOI
https://doi.org/10.3390/en17225588
Citations
1
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Heat Transfer Performance of a Device Utilizing an Asymmetric Pulsating Heat Pipe Structure Based on Global and Local Analysis

Fumin Shang, Kai Yang, Jianhong Liu, Dong Liu et al.
1 citations
Energies
Heat Transfer and Boiling Studies
0.21
article

Evaluation of the Heat Transfer Performance of a Device Utilizing an Asymmetric Pulsating Heat Pipe Structure Based on Global and Local Analysis

Fumin Shang, Kai Yang, Jianhong Liu, Dong Liu, Xin Cao, Chaofan Zheng
article en
1 citations

Abstract

PHPs (pulsating heat pipes) are widely used as an efficient heat transfer element in equipment thermal management and waste heat recovery due to their flexibility. The purpose of this study was to design a heat transfer device that utilizes an asymmetric pulsating heat pipe structure by adjusting the lengths of selected pipes within the entire circulation pipeline. In the experiment, a constant temperature water bath was used as the heat source, with heat dissipated in the condensing section via natural convection. An infrared thermal imager was used to record the temperature of the condensing section, and the local wall temperature distribution was measured in different channels of the condensing section. Based on an in-depth analysis of the wavelet frequency, the following research conclusions are drawn: Firstly, as the heat source temperature increases, the start-up time of the pulsating heat pipe is shortened, the operating state changes from start–stop–start to stable and continuous oscillation, and the oscillation mode changes from high amplitude and low frequency to low amplitude and high frequency. These changes are especially pronounced when the heat source temperature is 80 °C, which is when the thermal resistance reaches its lowest value of 0.0074 K/W, and the equivalent thermal conductivity reaches its highest value of 666.29 W/(m·K). Secondly, the flow and oscillation of the working fluid can be effectively promoted by appropriately shortening the length of the condensing section of the pulsating heat pipes or the heat transfer distance between the evaporation and condensing sections. Third, under a low-temperature heat source, the oscillation frequency of each channel of a pulsating heat pipe is found to be low based on wavelet analysis. However, as the heat source temperature increases, the energy content of the temperature signal of the working fluid in each channel changes from a low- to a high-frequency value, gradually converging to the same characteristic frequency. At this point, the working fluid in the pipes no longer flows randomly in multiple directions but rather in a single direction. Finally, we determined that the maximum oscillation frequency of working fluid in a PHP is around 0.7 HZ when using the water bath heating method.

EnergiesVol. 17(22)
Jilin Province Science and Technology Department (CN), Changchun Institute of Technology (CN)
Department of Science and Technology of Jilin Province
Affordable and clean energy
Openalex Percentile: Top 50%
Heat Transfer and Boiling Studies
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.