01 Characterization of NIS X-ray machine for Dosimetry in diagnostic application

The international protocols addressed finite beam qualities for each type of diagnostic radiology such as conventional, fluoroscopy, computed tomography and mammography. Moreover, for the dosimetry of each type in diagnostic radiology a certain ion chamber is used. In this work a set of X-ray beam qualities were established in accordance with the Technical Report Series (TRS) No.457-2007 of the International Atomic Energy Agency (IAEA). At the Ionizing Radiation Metrology Laboratory (IRML) of the National Institute of Standards (NIS), traceability is established for a set of ion chambers at the recommended beam qualities, ensuring dosimetry traceability to SI units through calibrations performed at the International Bureau of Weights and Measures (BIPM). The remaining ion chambers were calibrated locally at IRML-NIS. Two X-ray beam qualities were established for fluoroscopy and radiographic applications called RQR5 and RQR8. Moreover, three beam qualities were established for Computed Topography (CT) applications called RQT 8, 9 and 10. In mammography application, only one beam quality was validated by adding Mo filter with Half Value Layer (HVL) of 0.36 mm Al at 18 kV.

Authors

Institutions

Publication Details

Journal
Journal of Measurement Science and Applications (JMSA)
Published
2024-08-15
DOI
https://doi.org/10.21608/jmsa.2024.391432
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

01 Characterization of NIS X-ray machine for Dosimetry in diagnostic application

Reham Hamdy, Ahmed El Sersy
Journal of Measurement Science and Applications (JMSA)
Advanced Radiotherapy Techniques
article

01 Characterization of NIS X-ray machine for Dosimetry in diagnostic application

Reham Hamdy, Ahmed El Sersy
article en

Abstract

The international protocols addressed finite beam qualities for each type of diagnostic radiology such as conventional, fluoroscopy, computed tomography and mammography. Moreover, for the dosimetry of each type in diagnostic radiology a certain ion chamber is used. In this work a set of X-ray beam qualities were established in accordance with the Technical Report Series (TRS) No.457-2007 of the International Atomic Energy Agency (IAEA). At the Ionizing Radiation Metrology Laboratory (IRML) of the National Institute of Standards (NIS), traceability is established for a set of ion chambers at the recommended beam qualities, ensuring dosimetry traceability to SI units through calibrations performed at the International Bureau of Weights and Measures (BIPM). The remaining ion chambers were calibrated locally at IRML-NIS. Two X-ray beam qualities were established for fluoroscopy and radiographic applications called RQR5 and RQR8. Moreover, three beam qualities were established for Computed Topography (CT) applications called RQT 8, 9 and 10. In mammography application, only one beam quality was validated by adding Mo filter with Half Value Layer (HVL) of 0.36 mm Al at 18 kV.

Journal of Measurement Science and Applications (JMSA)Vol. 4(2)
National Institute of Standards (EG)
Openalex Percentile: Top 71%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

01 Characterization of NIS X-ray machine for Dosimetry in diagnostic application — Reham Hamdy, Ahmed El Sersy · Journal of Measurement Science and Applications (JMSA) (2024) | TGRS Research Map | TGRS