03 Protection Doses Standardization for metrological applications

This work accurately determined the radiation dose in radiation protection range using a PTW primary standard chamber model TN 32008. The characterization of the ion chamber used was performed at different radiation beam qualities. The performance of the chamber as a primary standard was studied in 137 Cs gamma source where the unit of absorbed dose in Gray was determined from its definition. Factors affecting the dose calculation such as operating voltage, saturation, and ion recombination were studied at the optimum conditions of the chamber usage. Moreover, the performance of the chamber as a primary standard dosemeter was extensively studied using the 60 Co gamma source and different X-ray beam qualities where the relation between its dose-to-collected charge (Gy/C) using the photon energy (keV) was determined. The detailed uncertainty budget was calculated for the used beam qualities. It was found that the chamber can be used in direct radiation dose determination as a primary standard chamber for wide photon energies from 42 keV (effective energy of 100 kV X-ray) to 1250 keV (60 Co) considering the relative stopping power of graphite to air correction and the relative attenuation of the precise beam quality to that of Cs-137 source. The uncertainty of the chamber Nk is 0.7% which shows an energy dependency.

Authors

Institutions

Publication Details

Journal
Journal of Measurement Science and Applications (JMSA)
Published
2024-08-15
DOI
https://doi.org/10.21608/jmsa.2024.391453
Primary Topic
Radioactive Decay and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

03 Protection Doses Standardization for metrological applications

salwa Nagib, Reham Hamdy, Ahmed R El Sersy
Journal of Measurement Science and Applications (JMSA)
Radioactive Decay and Measurement Techniques
article

03 Protection Doses Standardization for metrological applications

salwa Nagib, Reham Hamdy, Ahmed R El Sersy
article en

Abstract

This work accurately determined the radiation dose in radiation protection range using a PTW primary standard chamber model TN 32008. The characterization of the ion chamber used was performed at different radiation beam qualities. The performance of the chamber as a primary standard was studied in 137 Cs gamma source where the unit of absorbed dose in Gray was determined from its definition. Factors affecting the dose calculation such as operating voltage, saturation, and ion recombination were studied at the optimum conditions of the chamber usage. Moreover, the performance of the chamber as a primary standard dosemeter was extensively studied using the 60 Co gamma source and different X-ray beam qualities where the relation between its dose-to-collected charge (Gy/C) using the photon energy (keV) was determined. The detailed uncertainty budget was calculated for the used beam qualities. It was found that the chamber can be used in direct radiation dose determination as a primary standard chamber for wide photon energies from 42 keV (effective energy of 100 kV X-ray) to 1250 keV (60 Co) considering the relative stopping power of graphite to air correction and the relative attenuation of the precise beam quality to that of Cs-137 source. The uncertainty of the chamber Nk is 0.7% which shows an energy dependency.

Journal of Measurement Science and Applications (JMSA)Vol. 4(2)
National Institute of Standards (EG)
Openalex Percentile: Top 71%
Radioactive Decay and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

03 Protection Doses Standardization for metrological applications — salwa Nagib, Reham Hamdy, et al. · Journal of Measurement Science and Applications (JMSA) (2024) | TGRS Research Map | TGRS