Simulation and Economic Design of a Building Integrated Stand-alone Hybrid system

A thorough technical and financial analysis of the Hybrid Renewable Energy System (HRES) at the University of Badr is presented in this study. This paper seeks to determine whether it is possible to meet load demand using the system that has the lowest net present cost (NPC). In order to achieve the best minimum objective value modified whale optimizer is used to choose the number of units among photovoltaic, wind, and battery banks. The widely used HOMER software, other optimizers are applied and their results are compared with those obtained by the modified whale to confirm the system's dependability, an annual energy balance analysis and simulation performance are completed.Wind energy, battery cost, and load have a greater impact on NPC than other factors, according to sensitivity analysis.To evaluate the performance and dynamics of the system, modelling and simulation are performed using MATLAB-Simulink at different scenarios with maximum power point tracking (MPPT) and without MPPT and changing weather conditions speed and shown performance of state of charge of battery with change of weather.

Authors

Institutions

Publication Details

Journal
Suez Canal Engineering, Energy and Environmental Science
Published
2024-10-01
DOI
https://doi.org/10.21608/sceee.2024.318500.1042
Primary Topic
Transportation and Mobility Innovations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation and Economic Design of a Building Integrated Stand-alone Hybrid system

Sameh I. Selem, Mohamed A. Enany, Nada Elsayed Elmalt
Suez Canal Engineering, Energy and Environmental Science
Transportation and Mobility Innovations
article

Simulation and Economic Design of a Building Integrated Stand-alone Hybrid system

Sameh I. Selem, Mohamed A. Enany, Nada Elsayed Elmalt
article en

Abstract

A thorough technical and financial analysis of the Hybrid Renewable Energy System (HRES) at the University of Badr is presented in this study. This paper seeks to determine whether it is possible to meet load demand using the system that has the lowest net present cost (NPC). In order to achieve the best minimum objective value modified whale optimizer is used to choose the number of units among photovoltaic, wind, and battery banks. The widely used HOMER software, other optimizers are applied and their results are compared with those obtained by the modified whale to confirm the system's dependability, an annual energy balance analysis and simulation performance are completed.Wind energy, battery cost, and load have a greater impact on NPC than other factors, according to sensitivity analysis.To evaluate the performance and dynamics of the system, modelling and simulation are performed using MATLAB-Simulink at different scenarios with maximum power point tracking (MPPT) and without MPPT and changing weather conditions speed and shown performance of state of charge of battery with change of weather.

Suez Canal Engineering, Energy and Environmental ScienceVol. 2(2)
Zagazig University (EG), Faculty (United Kingdom) (GB), Engineering (Italy) (IT)
Openalex Percentile: Top 79%
Transportation and Mobility Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simulation and Economic Design of a Building Integrated Stand-alone Hybrid system — Sameh I. Selem, Mohamed A. Enany, et al. · Suez Canal Engineering, Energy and Environmental Science (2024) | TGRS Research Map | TGRS