New titanium mesh design method in customized bone regeneration of the jaws: preliminary study on a sample of 11 patients

The aim of this study is 1) to present a new method of virtually-designed custom made scaffolds to be employed in customized bone regeneration (CBR) for segmental jaw atrophies and 2) to evaluate long-term clinical results in terms of bone regeneration success and implant rehabilitation success. A total of 11 patients with edentulousness and bone atrophy in a localized area of the mandible or the maxilla were recruited for the study. To fulfill the research inquiries, CT images of the pre-regeneration mandibular or maxillary arch of each patient were collected. A dedicated Mevislab 2.4 software was employed to virtually design custom bone regeneration meshes designed to fit the atrophic sector of each patient's mandible or maxilla. Subsequently, a second Meshmixer software was used to refine the margins of each of the designed meshes. All patients underwent oral surgery, during which a mixture of autologous and heterologous bone in a 1:1 proportion was grafted into the atrophic site, a custom-made mesh was placed, and a resorbable membrane was inserted. The mesh was removed after this procedure, and implant rehabilitation was performed. All patients underwent the bone regeneration procedure, with eight undergoing titanium mesh removal. A total of seven patients completed implant rehabilitation. Average horizontal bone augmentation was 3.525 ± 1.36 mm; average vertical bone augmentation was 4.45 ± 2.22 mm. Implant survival was 92.85%. During the healing phase, complications occurred in 9.09% of patients. The use of dedicated software, Mevislab 2.4 and Meshmixer, for titanium mesh design is an accurate, predictable, effective, and quick-to-use method. The learning curve for design is uncomplicated and rapid. Mesh exposure does not necessarily lead to bone graft failure; this complication can be treated by chlorhexidine aids.

Authors

Institutions

Publication Details

Journal
Journal of Applied Cosmetology
Published
2024-10-25
DOI
https://doi.org/10.56609/jac.v42i2.386
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New titanium mesh design method in customized bone regeneration of the jaws: preliminary study on a sample of 11 patients

F. Melloni, Nicoletta Zerman, M. Beccherle, P. Faccioni et al.
Journal of Applied Cosmetology
Dental Implant Techniques and Outcomes
article

New titanium mesh design method in customized bone regeneration of the jaws: preliminary study on a sample of 11 patients

F. Melloni, Nicoletta Zerman, M. Beccherle, P. Faccioni, F. Balliu, M. Caroprese, G. Lobbia, P. Montagna, Daniele De Santis, E. Cagnin
article en

Abstract

The aim of this study is 1) to present a new method of virtually-designed custom made scaffolds to be employed in customized bone regeneration (CBR) for segmental jaw atrophies and 2) to evaluate long-term clinical results in terms of bone regeneration success and implant rehabilitation success. A total of 11 patients with edentulousness and bone atrophy in a localized area of the mandible or the maxilla were recruited for the study. To fulfill the research inquiries, CT images of the pre-regeneration mandibular or maxillary arch of each patient were collected. A dedicated Mevislab 2.4 software was employed to virtually design custom bone regeneration meshes designed to fit the atrophic sector of each patient's mandible or maxilla. Subsequently, a second Meshmixer software was used to refine the margins of each of the designed meshes. All patients underwent oral surgery, during which a mixture of autologous and heterologous bone in a 1:1 proportion was grafted into the atrophic site, a custom-made mesh was placed, and a resorbable membrane was inserted. The mesh was removed after this procedure, and implant rehabilitation was performed. All patients underwent the bone regeneration procedure, with eight undergoing titanium mesh removal. A total of seven patients completed implant rehabilitation. Average horizontal bone augmentation was 3.525 ± 1.36 mm; average vertical bone augmentation was 4.45 ± 2.22 mm. Implant survival was 92.85%. During the healing phase, complications occurred in 9.09% of patients. The use of dedicated software, Mevislab 2.4 and Meshmixer, for titanium mesh design is an accurate, predictable, effective, and quick-to-use method. The learning curve for design is uncomplicated and rapid. Mesh exposure does not necessarily lead to bone graft failure; this complication can be treated by chlorhexidine aids.

Journal of Applied CosmetologyVol. 42(2)
University of Foggia (IT), University of Verona (IT), Ospedale Sacro Cuore Don Calabria (IT), Istituti di Ricovero e Cura a Carattere Scientifico (IT)
Good health and well-being
Openalex Percentile: Top 69%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines