Passive shimming of a 3T cryogen-free animal magnetic resonance imaging superconducting magnet with dense shim tray slots and small residual magnetic force

Passive shimming is widely used in magnetic resonance imaging (MRI) systems due to its excellent efficacy and cost-effectiveness. However, conventional shim tray structures have difficulty in effectively adjusting magnetic field distributions under specific conditions. This limitation can lead to insufficient cancellation of harmonics and result in significant residual forces on the trays, impeding accurate placement of the trays. In this study, instead of using the conventional design of the shim tray slot, we propose a dedicated passive shimming tray tailored for 3T cryogen-free animal MRI superconducting magnets. Passive shimming experiments were conducted to evaluate the performance of this novel design, in which we were able to improve the peak-to-peak magnetic field homogeneity within the 180 mm diameter imaging region, reducing peak-to-peak (p-p) variation from 349.35 ppm to 19.08 ppm. Furthermore, the p-p homogeneity of the magnetic field measured at the imaging area with a diameter of spherical volume (DSV) of 160 mm reached 8.67 ppm. In addition, we strictly controlled the residual magnetic force of the shim tray to ensure its accurate placement. The experimental results indicate that the proposed structural optimization method and the residual magnetic force control strategy show potential in high-field MRI instruments requiring high homogeneity and handling of high residual magnetic force.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2024-11-01
DOI
https://doi.org/10.1063/5.0215247
Citations
6
Primary Topic
Superconducting Materials and Applications
Type
article
Field-Weighted Citation Impact
1.11

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Passive shimming of a 3T cryogen-free animal magnetic resonance imaging superconducting magnet with dense shim tray slots and small residual magnetic force

Wenchen Wang, Jinshui Sun, H.S. Chen, Shunzhong Chen et al.
6 citations
Review of Scientific Instruments
Superconducting Materials and Applications
1.11
article

Passive shimming of a 3T cryogen-free animal magnetic resonance imaging superconducting magnet with dense shim tray slots and small residual magnetic force

Wenchen Wang, Jinshui Sun, H.S. Chen, Shunzhong Chen, Hui Wang, Feng Liu, Yaohui Wang, Gu-Yue Zhou, Weimin Wang, Jinhao Liu, Pengfei Wu
article en
6 citations

Abstract

Passive shimming is widely used in magnetic resonance imaging (MRI) systems due to its excellent efficacy and cost-effectiveness. However, conventional shim tray structures have difficulty in effectively adjusting magnetic field distributions under specific conditions. This limitation can lead to insufficient cancellation of harmonics and result in significant residual forces on the trays, impeding accurate placement of the trays. In this study, instead of using the conventional design of the shim tray slot, we propose a dedicated passive shimming tray tailored for 3T cryogen-free animal MRI superconducting magnets. Passive shimming experiments were conducted to evaluate the performance of this novel design, in which we were able to improve the peak-to-peak magnetic field homogeneity within the 180 mm diameter imaging region, reducing peak-to-peak (p-p) variation from 349.35 ppm to 19.08 ppm. Furthermore, the p-p homogeneity of the magnetic field measured at the imaging area with a diameter of spherical volume (DSV) of 160 mm reached 8.67 ppm. In addition, we strictly controlled the residual magnetic force of the shim tray to ensure its accurate placement. The experimental results indicate that the proposed structural optimization method and the residual magnetic force control strategy show potential in high-field MRI instruments requiring high homogeneity and handling of high residual magnetic force.

Review of Scientific InstrumentsVol. 95(11)
The University of Queensland (AU), Chinese Academy of Sciences (CN), Peking University (CN), University of Chinese Academy of Sciences (CN), Huazhong University of Science and Technology (CN), Xi'an Jiaotong University (CN)
National Natural Science Foundation of China, Development and Reform Commission of Shenzhen Municipality, Beijing Nova Program
Openalex Percentile: Top 24%
Superconducting Materials and Applications
1.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.