Application of the percentage differential relay and stator earth fault protection in synchronous generators

Abstract Synchronous generators play a vital role in the power system. The relay protection distributed in the system can quickly remove the fault, effectively respond to it, and solve the problem. In this paper, the characteristics of a synchronous generator neutral ungrounded are analyzed when various unsymmetrical and symmetrical faults occur in the internal and external areas, and the percentage differential relay is used to solve the problem of short circuit faults. For the single line-to-ground fault, the stator earth fault protection is also introduced to compensate for the shortcomings of the generator neutral ungrounded. The simulation software MATLAB/Simulink is applied for modeling and analysis, and the strategy of composite protection solves the problem of unsymmetrical failure for the neutral point ungrounding generator.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2024-10-01
DOI
https://doi.org/10.1088/1742-6596/2878/1/012001
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of the percentage differential relay and stator earth fault protection in synchronous generators

W T Hsu, Chia-Wei Huang, Sha Wang
Journal of Physics Conference Series
Power Systems Fault Detection
article

Application of the percentage differential relay and stator earth fault protection in synchronous generators

W T Hsu, Chia-Wei Huang, Sha Wang
article en

Abstract

Abstract Synchronous generators play a vital role in the power system. The relay protection distributed in the system can quickly remove the fault, effectively respond to it, and solve the problem. In this paper, the characteristics of a synchronous generator neutral ungrounded are analyzed when various unsymmetrical and symmetrical faults occur in the internal and external areas, and the percentage differential relay is used to solve the problem of short circuit faults. For the single line-to-ground fault, the stator earth fault protection is also introduced to compensate for the shortcomings of the generator neutral ungrounded. The simulation software MATLAB/Simulink is applied for modeling and analysis, and the strategy of composite protection solves the problem of unsymmetrical failure for the neutral point ungrounding generator.

Journal of Physics Conference SeriesVol. 2878(1)
Zhaoqing University (CN)
Openalex Percentile: Top 76%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Application of the percentage differential relay and stator earth fault protection in synchronous generators — W T Hsu, Chia-Wei Huang, et al. · Journal of Physics Conference Series (2024) | TGRS Research Map | TGRS