The Development and Validation of a Glaucoma Health Score for Glaucoma Screening Based on Clinical Parameters and Optical Coherence Tomography Metrics

<b>Background/Objectives:</b> This study aims to develop and validate a Glaucoma Health Score (GHS) that incorporates multiple individual glaucoma risk factors to enhance glaucoma detection in screening environments. <b>Methods:</b> The GHS was developed using a retrospective dataset from two clinical sites, including both eyes of glaucoma patients and controls. The model incorporated age, central corneal thickness, intraocular pressure, pattern standard deviation from a visual field threshold 24-2 test, and two parameters from an optical coherence tomography (OCT) test: the average circumpapillary retinal nerve fiber layer thickness and the minimum thickness of the six sectors of the macular ganglion cell plus the inner plexiform layer. The GHS was then validated in two independent datasets: one from primary care sites using Maestro OCT data (test dataset 1) and another from an academic center using DRI OCT Triton (test dataset 2). <b>Results:</b> Both eyes of 51 glaucoma patients and 67 controls were included in the development dataset. Setting the GHS cutoff at 75 points out of 100, test dataset 1, which comprised 41 subjects with glaucoma and 41 healthy controls, achieved an area under the receiver operating characteristic curve (AUROC) of 0.98, with a sensitivity of 71% and specificity of 98%; test dataset 2, which included 53 patients with glaucoma and 53 healthy controls, resulted in an AUROC of 0.95, with a sensitivity of 75% and specificity of 96%. A decision curve analysis across all datasets demonstrated a higher net benefit for the GHS model compared to individual OCT parameters. <b>Conclusions:</b> The GHS offers a feasible, standardized approach for early detection of glaucoma, providing strong specificity and acceptable sensitivity, with clear decision-making benefits in screening settings.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-11-08
DOI
https://doi.org/10.3390/jcm13226728
Citations
2
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
1.08
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Development and Validation of a Glaucoma Health Score for Glaucoma Screening Based on Clinical Parameters and Optical Coherence Tomography Metrics

Sasan Moghimi, Ashley Speilburg, Christopher K. Lee, Juan David Arias et al.
2 citations
Journal of Clinical Medicine
Glaucoma and retinal disorders
1.08
article

The Development and Validation of a Glaucoma Health Score for Glaucoma Screening Based on Clinical Parameters and Optical Coherence Tomography Metrics

Sasan Moghimi, Ashley Speilburg, Christopher K. Lee, Juan David Arias, Robert Neal Weinreb, Huiyuan Hou, Nevin W. El-Nimri, Takashi Nishida, Michael Chaglasian, Antonio Guzmán, Timothy Bossie, Yu Xuan Yong, Linda M. Zangwill, Mary K. Durbin
article en
2 citations

Abstract

<b>Background/Objectives:</b> This study aims to develop and validate a Glaucoma Health Score (GHS) that incorporates multiple individual glaucoma risk factors to enhance glaucoma detection in screening environments. <b>Methods:</b> The GHS was developed using a retrospective dataset from two clinical sites, including both eyes of glaucoma patients and controls. The model incorporated age, central corneal thickness, intraocular pressure, pattern standard deviation from a visual field threshold 24-2 test, and two parameters from an optical coherence tomography (OCT) test: the average circumpapillary retinal nerve fiber layer thickness and the minimum thickness of the six sectors of the macular ganglion cell plus the inner plexiform layer. The GHS was then validated in two independent datasets: one from primary care sites using Maestro OCT data (test dataset 1) and another from an academic center using DRI OCT Triton (test dataset 2). <b>Results:</b> Both eyes of 51 glaucoma patients and 67 controls were included in the development dataset. Setting the GHS cutoff at 75 points out of 100, test dataset 1, which comprised 41 subjects with glaucoma and 41 healthy controls, achieved an area under the receiver operating characteristic curve (AUROC) of 0.98, with a sensitivity of 71% and specificity of 98%; test dataset 2, which included 53 patients with glaucoma and 53 healthy controls, resulted in an AUROC of 0.95, with a sensitivity of 75% and specificity of 96%. A decision curve analysis across all datasets demonstrated a higher net benefit for the GHS model compared to individual OCT parameters. <b>Conclusions:</b> The GHS offers a feasible, standardized approach for early detection of glaucoma, providing strong specificity and acceptable sensitivity, with clear decision-making benefits in screening settings.

Journal of Clinical MedicineVol. 13(22)
University of San Diego (US), New England College of Optometry (US), University of California San Diego (US), Illinois College of Optometry (US)
Openalex Percentile: Top 21%
Glaucoma and retinal disorders
1.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.