Adaptive Weighted Bregman Huber Total Variation Method for Terahertz Computed Tomography

ABSTRACT To improve the image quality of terahertz (THz) continuous wave (CW) computed tomography (CT) under sparse‐view projections, a sparse‐view adaptive‐weighted Bregman Huber total variation (AW‐BHTV) method is proposed and experimentally evaluated at 0.11 THz. The Huber function is served as the fidelity term and TV function is worked for the regularization term, optimized by the adaptive weights, incorporating with iterative algorithms containing the modified simultaneous algebraic reconstruction technique (MSART) and the iterative filtered back‐projection (FBP). Sparse‐view reconstruction experiments are carefully implemented via polystyrene (PS) foam samples: Sample 1 and Sample 2, respectively. Under 20 projection angles by MSART based AW‐BHTV, the values of rooted mean‐square‐error (RMSE), peak signal‐to‐noise ratio (PSNR), structure similarity (SSIM) and feature similarity (FSIM) are 0.0061, 22.1427, 0.8738 and 0.9902 for Sample 1 together with 0.0051, 22.9101, 0.8376 and 0.9885 for Sample 2 separately. All of the results above suggest that the proposed AW‐BHTV method can effectively protect image details and strengthen image quality in sparse‐view THz CW CT.

Authors

Institutions

Publication Details

Journal
Microwave and Optical Technology Letters
Published
2024-11-01
DOI
https://doi.org/10.1002/mop.70023
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adaptive Weighted Bregman Huber Total Variation Method for Terahertz Computed Tomography

Xingzeng Cha, Dakun Lai, En Li
1 citations
Microwave and Optical Technology Letters
Medical Imaging Techniques and Applications
0.40
article

Adaptive Weighted Bregman Huber Total Variation Method for Terahertz Computed Tomography

Xingzeng Cha, Dakun Lai, En Li
article en
1 citations

Abstract

ABSTRACT To improve the image quality of terahertz (THz) continuous wave (CW) computed tomography (CT) under sparse‐view projections, a sparse‐view adaptive‐weighted Bregman Huber total variation (AW‐BHTV) method is proposed and experimentally evaluated at 0.11 THz. The Huber function is served as the fidelity term and TV function is worked for the regularization term, optimized by the adaptive weights, incorporating with iterative algorithms containing the modified simultaneous algebraic reconstruction technique (MSART) and the iterative filtered back‐projection (FBP). Sparse‐view reconstruction experiments are carefully implemented via polystyrene (PS) foam samples: Sample 1 and Sample 2, respectively. Under 20 projection angles by MSART based AW‐BHTV, the values of rooted mean‐square‐error (RMSE), peak signal‐to‐noise ratio (PSNR), structure similarity (SSIM) and feature similarity (FSIM) are 0.0061, 22.1427, 0.8738 and 0.9902 for Sample 1 together with 0.0051, 22.9101, 0.8376 and 0.9885 for Sample 2 separately. All of the results above suggest that the proposed AW‐BHTV method can effectively protect image details and strengthen image quality in sparse‐view THz CW CT.

Microwave and Optical Technology LettersVol. 66(11)
University of Electronic Science and Technology of China (CN)
Openalex Percentile: Top 33%
Medical Imaging Techniques and Applications
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.