HaptiScan: A Haptically-Enabled Robotic Ultrasound System for Remote Medical Diagnostics

Medical ultrasound is a widely used diagnostic imaging modality that provides real-time imaging at a relatively low cost. However, its widespread application is hindered by the need for expert operation, particularly in remote regional areas where trained sonographers are scarce. This paper presents the development of HaptiScan, a state-of-the-art telerobotic ultrasound system equipped with haptic feedback. The system utilizes a commercially available robotic manipulator, the UR5 robot from Universal Robots, integrated with a force/torque sensor and the Phantom Omni haptic device. This configuration enables skilled sonographers to remotely conduct ultrasound procedures via an internet connection, addressing both the geographic and ergonomic limitations faced in traditional sonography. Key innovative features of the system include real-time force feedback, ensuring that sonographers can precisely control the ultrasound probe from a remote location. The system is further enhanced by safety measures such as over-force sensing, patient discomfort monitoring, and emergency stop mechanisms. Quantitative indicators of the system’s performance include successful teleoperation over long distances with time delays, as demonstrated in simulations. These simulations validate the system’s control methodologies, showing stable performance with force feedback under varying time delays and distances. Additionally, the UR5 manipulator’s precision, kinematic, and dynamic models are mathematically formulated to optimize teleoperation. The results highlight the effectiveness of the proposed system in overcoming the technical challenges of remote ultrasound procedures, offering a viable solution for real-world telemedicine applications.

Authors

Institutions

Publication Details

Journal
Robotics
Published
2024-11-10
DOI
https://doi.org/10.3390/robotics13110164
Citations
9
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
1.66
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

HaptiScan: A Haptically-Enabled Robotic Ultrasound System for Remote Medical Diagnostics

Taoming Liu, Zoran Najdovski, Siamak Pedrammehr, Stephen T. Hilton et al.
9 citations
Robotics
Soft Robotics and Applications
1.66
article

HaptiScan: A Haptically-Enabled Robotic Ultrasound System for Remote Medical Diagnostics

Taoming Liu, Zoran Najdovski, Siamak Pedrammehr, Stephen T. Hilton, Houshyar Asadi, Mohammad Reza Chalak Qazani, Sameer Deshpande, Hamid Abdi, Michael Fielding, James Mullins
article en
9 citations

Abstract

Medical ultrasound is a widely used diagnostic imaging modality that provides real-time imaging at a relatively low cost. However, its widespread application is hindered by the need for expert operation, particularly in remote regional areas where trained sonographers are scarce. This paper presents the development of HaptiScan, a state-of-the-art telerobotic ultrasound system equipped with haptic feedback. The system utilizes a commercially available robotic manipulator, the UR5 robot from Universal Robots, integrated with a force/torque sensor and the Phantom Omni haptic device. This configuration enables skilled sonographers to remotely conduct ultrasound procedures via an internet connection, addressing both the geographic and ergonomic limitations faced in traditional sonography. Key innovative features of the system include real-time force feedback, ensuring that sonographers can precisely control the ultrasound probe from a remote location. The system is further enhanced by safety measures such as over-force sensing, patient discomfort monitoring, and emergency stop mechanisms. Quantitative indicators of the system’s performance include successful teleoperation over long distances with time delays, as demonstrated in simulations. These simulations validate the system’s control methodologies, showing stable performance with force feedback under varying time delays and distances. Additionally, the UR5 manipulator’s precision, kinematic, and dynamic models are mathematically formulated to optimize teleoperation. The results highlight the effectiveness of the proposed system in overcoming the technical challenges of remote ultrasound procedures, offering a viable solution for real-world telemedicine applications.

RoboticsVol. 13(11)
Deakin University (AU), Telstra (Australia) (AU), Sohar University (OM), Tabriz Islamic Arts University (IR)
Openalex Percentile: Top 17%
Soft Robotics and Applications
1.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.