Abstract 4145896: Terminal Rhythm of the Worldwide First Genetically Modified Porcine-to-Human Xenotransplantation

Background: The worldwide first genetically modified porcine-to-human cardiac xenotransplantation was successfully performed in January 2022 at the University of Maryland with the recipient surviving 60 days. Aim: Assess the ECG parameters and cardiac rhythm during the death of the worldwide first porcine-to-human xenotransplant. Methods: Continuous 6-lead ECG telemetry was used to analyze ECG parameters and cardiac rhythm during the final 9 minutes after withdrawal of life support. Results: At the time of withdrawal (W), the patient was in sinus rhythm (70bpm, PR interval 280ms, right bundle branch block (RBBB) with QRS 140ms, QT 400ms; Figure). PR prolongation up to 360ms with loss of P wave was noted at W+2:55min. Irregular junctional rhythm with blocked PACs and bradycardia (23 bpm) occurred around W+3:25min. At that time, widening of RBBB to 160ms with non-specific repolarization abnormalities and QT prolongation were observed. At W+4:30min, increasing pauses of up to 8.5s with mild QRS axis shift occurred. At W+6min, asystole (up to 20s) with rare PVCs from the left anterolateral LV base were seen. Final rhythm at W+6min consisted of ventricular escape beats from the infero-basal LV before electrical activity ceased at W+6:45min. No other atrial or ventricular arrhythmias were noted. Conclusion: The porcine-to-human cardiac xenotransplant showed a terminal rhythm of bradycardia, sinus arrest, and junctional and ventricular escape beats. This is consistent with ischemia-related failure of impulse generation, slowing intra-atrial/AV-conduction delay, and failure of impulse propagation. Notably, no tachyarrhythmias were seen despite ectopic atrial and ventricular beats with prolongation of depolarization and repolarization. This is similar to traditional terminal rhythms observed in humans and does not suggest unexpected arrhythmic proclivities between pig myocardium and the human environment (“pig heart in human body”).

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-11
DOI
https://doi.org/10.1161/circ.150.suppl_1.4145896
Primary Topic
Xenotransplantation and immune response
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4145896: Terminal Rhythm of the Worldwide First Genetically Modified Porcine-to-Human Xenotransplantation

Manjula Ananthram, Richard Amara, Timm Dickfeld, Alison Grazioli et al.
Circulation
Xenotransplantation and immune response
article

Abstract 4145896: Terminal Rhythm of the Worldwide First Genetically Modified Porcine-to-Human Xenotransplantation

Manjula Ananthram, Richard Amara, Timm Dickfeld, Alison Grazioli, Muhammad Mohiuddin, Justin Brilliant, Bartley P. Griffith, Oneib Khan, Susie Hong-Zohlman, Mahdokht Parsirad, Ubaid Khan, Stephen R. Shorofsky, Erika Feller
article en

Abstract

Background: The worldwide first genetically modified porcine-to-human cardiac xenotransplantation was successfully performed in January 2022 at the University of Maryland with the recipient surviving 60 days. Aim: Assess the ECG parameters and cardiac rhythm during the death of the worldwide first porcine-to-human xenotransplant. Methods: Continuous 6-lead ECG telemetry was used to analyze ECG parameters and cardiac rhythm during the final 9 minutes after withdrawal of life support. Results: At the time of withdrawal (W), the patient was in sinus rhythm (70bpm, PR interval 280ms, right bundle branch block (RBBB) with QRS 140ms, QT 400ms; Figure). PR prolongation up to 360ms with loss of P wave was noted at W+2:55min. Irregular junctional rhythm with blocked PACs and bradycardia (23 bpm) occurred around W+3:25min. At that time, widening of RBBB to 160ms with non-specific repolarization abnormalities and QT prolongation were observed. At W+4:30min, increasing pauses of up to 8.5s with mild QRS axis shift occurred. At W+6min, asystole (up to 20s) with rare PVCs from the left anterolateral LV base were seen. Final rhythm at W+6min consisted of ventricular escape beats from the infero-basal LV before electrical activity ceased at W+6:45min. No other atrial or ventricular arrhythmias were noted. Conclusion: The porcine-to-human cardiac xenotransplant showed a terminal rhythm of bradycardia, sinus arrest, and junctional and ventricular escape beats. This is consistent with ischemia-related failure of impulse generation, slowing intra-atrial/AV-conduction delay, and failure of impulse propagation. Notably, no tachyarrhythmias were seen despite ectopic atrial and ventricular beats with prolongation of depolarization and repolarization. This is similar to traditional terminal rhythms observed in humans and does not suggest unexpected arrhythmic proclivities between pig myocardium and the human environment (“pig heart in human body”).

CirculationVol. 150(Suppl_1)
University of Maryland, Baltimore (US), University of Maryland Medical Center (US)
Responsible consumption and production
Openalex Percentile: Top 62%
Xenotransplantation and immune response
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.