Abstract 4136983: Estimating Atrial Fibrillation Rate in Patients Using Artificial Intelligence Referenced to Tissue Action Potentials

Background: Ablation by pulmonary vein isolation (PVI) is the most effective approach to treat atrial fibrillation (AF), but 30-40% of patients may not respond. Studies including the CAPLA trial suggest that ablating sites of rapid activation on the posterior left atrial wall or elsewhere may improve success. However, AF rate is rarely calibrated and, since electrograms often include noise or far field activity, may overestimate rate (underestimate cycle length) at many sites. Hypothesis: We hypothesized that artificial intelligence (AI) algorithms may more accurately indicate local AF rate, by excluding spurious activations referenced to simultaneous monophasic action potential (MAP) recordings, compared to conventional measurements. Methods: We studied N=303 AF patients at ablation (68.2±8.0 years, 17.8% females, 72.9% non-paroxysmal AF). Patients were matched N=229 into development and one quarter (N=74) into hold-out test cohorts. Patients underwent AF mapping using multipolar catheters, and a subset with MAP catheters (MedFact, GmbH). We used the development set to train an AI algorithm to reliably detect AF activations, which we compared in the test cohort to a standard dV/dt approach referenced to adjacent MAPs within 2 mm (N=20 patients) and manually annotated activations (N=64 patients). Results: Fig A shows AF in a 66 year old woman, where dV/dt often marked non-physiological activations within repolarization shown in the adjacent MAP. Conversely, the AI system excluded spurious deflections and better correlated with experts (black). In summary, Fig. B shows that AI provided a higher F1 score than dV/dt compared to MAPs (median[IQR]: 0.86 [0.5 - 1] vs. 0.67 [0.40 - 0.73], p<0.01) and experts (0.89 [0.73 - 1] vs. 0.72 [0.60 - 0.89]], p<0.01). Fig C shows that the AI approach better identified AF cycle length (rate; blue) than standard approaches (green) that substantially underestimate cycle length (p<0.05). Conclusions: In this large registry, a novel AI-based approach more accurately detected AF rates in clinical electrograms, referenced to experts and action potential recordings, than standard approaches which overestimated rate. AI may improve characterization of AF activity within the atria.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-11
DOI
https://doi.org/10.1161/circ.150.suppl_1.4136983
Primary Topic
Healthcare Systems and Public Health
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4136983: Estimating Atrial Fibrillation Rate in Patients Using Artificial Intelligence Referenced to Tissue Action Potentials

Sanjiv M. Narayan, Samuel Ruipérez-Campillo, Rafael San Juan, Suhaas Anbazhakan et al.
Circulation
Healthcare Systems and Public Health
article

Abstract 4136983: Estimating Atrial Fibrillation Rate in Patients Using Artificial Intelligence Referenced to Tissue Action Potentials

Sanjiv M. Narayan, Samuel Ruipérez-Campillo, Rafael San Juan, Suhaas Anbazhakan, Miguel Rodrigo
article en

Abstract

Background: Ablation by pulmonary vein isolation (PVI) is the most effective approach to treat atrial fibrillation (AF), but 30-40% of patients may not respond. Studies including the CAPLA trial suggest that ablating sites of rapid activation on the posterior left atrial wall or elsewhere may improve success. However, AF rate is rarely calibrated and, since electrograms often include noise or far field activity, may overestimate rate (underestimate cycle length) at many sites. Hypothesis: We hypothesized that artificial intelligence (AI) algorithms may more accurately indicate local AF rate, by excluding spurious activations referenced to simultaneous monophasic action potential (MAP) recordings, compared to conventional measurements. Methods: We studied N=303 AF patients at ablation (68.2±8.0 years, 17.8% females, 72.9% non-paroxysmal AF). Patients were matched N=229 into development and one quarter (N=74) into hold-out test cohorts. Patients underwent AF mapping using multipolar catheters, and a subset with MAP catheters (MedFact, GmbH). We used the development set to train an AI algorithm to reliably detect AF activations, which we compared in the test cohort to a standard dV/dt approach referenced to adjacent MAPs within 2 mm (N=20 patients) and manually annotated activations (N=64 patients). Results: Fig A shows AF in a 66 year old woman, where dV/dt often marked non-physiological activations within repolarization shown in the adjacent MAP. Conversely, the AI system excluded spurious deflections and better correlated with experts (black). In summary, Fig. B shows that AI provided a higher F1 score than dV/dt compared to MAPs (median[IQR]: 0.86 [0.5 - 1] vs. 0.67 [0.40 - 0.73], p<0.01) and experts (0.89 [0.73 - 1] vs. 0.72 [0.60 - 0.89]], p<0.01). Fig C shows that the AI approach better identified AF cycle length (rate; blue) than standard approaches (green) that substantially underestimate cycle length (p<0.05). Conclusions: In this large registry, a novel AI-based approach more accurately detected AF rates in clinical electrograms, referenced to experts and action potential recordings, than standard approaches which overestimated rate. AI may improve characterization of AF activity within the atria.

CirculationVol. 150(Suppl_1)
Universitat de València (ES), Brocade (United States) (US), ETH Zurich (CH), Stanford University (US)
Openalex Percentile: Top 70%
Healthcare Systems and Public Health
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.