Abstract 4113405: The Role of Cardiac Power Output and Stroke Work Index in Balloon Pulmonary Angioplasty Therapy for Chronic Thromboembolic Pulmonary Hypertension

Background: Right ventricular (RV) and left ventricular (LV) measures of cardiac power output (CPO) and stroke work index (SWI) are existing markers of cardiac function and clinical outcomes. These metrics have not been used to evaluate the effects of balloon pulmonary angioplasty (BPA) therapy in patients with chronic thromboembolic pulmonary hypertension (CTEPH). Methods: CTEPH patients who underwent at least six BPA sessions and were included in the UC San Diego BPA registry were included for analysis. Left and right ventricular CPO and SWI during each session were recorded. Cardiac output was measured using the thermodilution technique. Differences in continuous variable measurements before versus after BPA therapy were evaluated using the Student T-test. P-value <0.05 was significant. Results: A total of 66 subjects underwent six consecutive BPA sessions (55.5% female, BMI 28.3±6.10kg/m 2 ,16.7% prior pulmonary thromboendarterectomy surgery) and were included for analysis. Measurements of RV function, including RVCPO (Pre-BPA 0.38±0.14 vs Post-BPA 0.30±0.13 W, p=0.001)(Figure 1) and RVSWI (Pre-BPA 16.52±5.09 vs Post-BPA 14.14±4.00 g*m/beat/m 2 , p=0.004) significantly decreased after BPA therapy. Measurements of LV function, including LVCPO (Pre-BPA 1.00±0.32 vs Post-BPA 1.04±0.31 W, p=0.523) (Figure 2) and LVSWI (Pre-BPA 37.13±10.14 vs Post-BPA 39.73±9.37 g*m/beat/m 2 , p=0.152) did not change significantly after BPA therapy. The ratio of LVCPO/RVCPO increased in stepwise fashion from baseline to the last BPA session (2.82± 0.95 vs. 3.54±1.31 W, p<0.001)(Figure 3). Conclusions: Hemodynamic work expended by the RV decreased after BPA therapy, while work expended by the LV remained unchanged during BPA therapy. The ratio of LV-to-RV work increased in a stepwise manner during consecutive BPA sessions. These measurements may be useful parameters to monitor clinical response to BPA therapy.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-11
DOI
https://doi.org/10.1161/circ.150.suppl_1.4113405
Primary Topic
Pulmonary Hypertension Research and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4113405: The Role of Cardiac Power Output and Stroke Work Index in Balloon Pulmonary Angioplasty Therapy for Chronic Thromboembolic Pulmonary Hypertension

Ehtisham Mahmud, David Poch, Alma Fregoso, Lawrence Ang et al.
Circulation
Pulmonary Hypertension Research and Treatments
article

Abstract 4113405: The Role of Cardiac Power Output and Stroke Work Index in Balloon Pulmonary Angioplasty Therapy for Chronic Thromboembolic Pulmonary Hypertension

Ehtisham Mahmud, David Poch, Alma Fregoso, Lawrence Ang, Paul Chavez, Taylor Buchalla, JENNY YANG, Jonathan Omens, N. Nashed, Hyong Kim
article en

Abstract

Background: Right ventricular (RV) and left ventricular (LV) measures of cardiac power output (CPO) and stroke work index (SWI) are existing markers of cardiac function and clinical outcomes. These metrics have not been used to evaluate the effects of balloon pulmonary angioplasty (BPA) therapy in patients with chronic thromboembolic pulmonary hypertension (CTEPH). Methods: CTEPH patients who underwent at least six BPA sessions and were included in the UC San Diego BPA registry were included for analysis. Left and right ventricular CPO and SWI during each session were recorded. Cardiac output was measured using the thermodilution technique. Differences in continuous variable measurements before versus after BPA therapy were evaluated using the Student T-test. P-value <0.05 was significant. Results: A total of 66 subjects underwent six consecutive BPA sessions (55.5% female, BMI 28.3±6.10kg/m 2 ,16.7% prior pulmonary thromboendarterectomy surgery) and were included for analysis. Measurements of RV function, including RVCPO (Pre-BPA 0.38±0.14 vs Post-BPA 0.30±0.13 W, p=0.001)(Figure 1) and RVSWI (Pre-BPA 16.52±5.09 vs Post-BPA 14.14±4.00 g*m/beat/m 2 , p=0.004) significantly decreased after BPA therapy. Measurements of LV function, including LVCPO (Pre-BPA 1.00±0.32 vs Post-BPA 1.04±0.31 W, p=0.523) (Figure 2) and LVSWI (Pre-BPA 37.13±10.14 vs Post-BPA 39.73±9.37 g*m/beat/m 2 , p=0.152) did not change significantly after BPA therapy. The ratio of LVCPO/RVCPO increased in stepwise fashion from baseline to the last BPA session (2.82± 0.95 vs. 3.54±1.31 W, p<0.001)(Figure 3). Conclusions: Hemodynamic work expended by the RV decreased after BPA therapy, while work expended by the LV remained unchanged during BPA therapy. The ratio of LV-to-RV work increased in a stepwise manner during consecutive BPA sessions. These measurements may be useful parameters to monitor clinical response to BPA therapy.

CirculationVol. 150(Suppl_1)
University of California San Diego (US)
Good health and well-being
Openalex Percentile: Top 62%
Pulmonary Hypertension Research and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.