Numerical investigation on effects of steel I-section beams on the blast resistance of a stiffened steel tank under blast loading

The hazardous chemical storage tank faces a vital explosion risk, making reliability a critical concern. This study investigates the horizontal stiffening ring as an effective anti-blast measure to enhance the reliability of steel tanks under explosive conditions. Through numerical examination based on CONWEP model, we assessed the impact of vertical spacing between adjacent horizontal stiffening rings and their dimensions on the tank's blast resistance and overall structural integrity. The results suggest that a marked improvement in the tank's reliability and blast resistance with the addition of stiffening rings as horizontal stiffeners. The deformation shapes of the stiffened steel tank were less pronounced, and the radial displacements were smaller compared to an unstiffened steel tank. Additionally, the addition of horizontal stiffening rings enhanced the overall stiffness and stability of the steel tank. Furthermore, larger beam dimensions contribute to increased bending and shear stiffness, resulting in smaller deformations and better blast resistance of the steel tank.

Authors

Publication Details

Journal
Eksploatacja i Niezawodnosc - Maintenance and Reliability
Published
2024-11-11
DOI
https://doi.org/10.17531/ein/195802
Primary Topic
Structural Response to Dynamic Loads
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical investigation on effects of steel I-section beams on the blast resistance of a stiffened steel tank under blast loading

Qi Zhang, Y.-L. Pi, Juncheng Jiang, Song Lin et al.
Eksploatacja i Niezawodnosc - Maintenance and Reliability
Structural Response to Dynamic Loads
article

Numerical investigation on effects of steel I-section beams on the blast resistance of a stiffened steel tank under blast loading

Qi Zhang, Y.-L. Pi, Juncheng Jiang, Song Lin, Zhixiang Xing, Yunhao Li
article en

Abstract

The hazardous chemical storage tank faces a vital explosion risk, making reliability a critical concern. This study investigates the horizontal stiffening ring as an effective anti-blast measure to enhance the reliability of steel tanks under explosive conditions. Through numerical examination based on CONWEP model, we assessed the impact of vertical spacing between adjacent horizontal stiffening rings and their dimensions on the tank's blast resistance and overall structural integrity. The results suggest that a marked improvement in the tank's reliability and blast resistance with the addition of stiffening rings as horizontal stiffeners. The deformation shapes of the stiffened steel tank were less pronounced, and the radial displacements were smaller compared to an unstiffened steel tank. Additionally, the addition of horizontal stiffening rings enhanced the overall stiffness and stability of the steel tank. Furthermore, larger beam dimensions contribute to increased bending and shear stiffness, resulting in smaller deformations and better blast resistance of the steel tank.

Eksploatacja i Niezawodnosc - Maintenance and ReliabilityVol. 27(2)
National Natural Science Foundation of China, Changzhou University
Openalex Percentile: Top 77%
Structural Response to Dynamic Loads
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.