The Prediction of the Leakage Airflow Rate Using the Supply and Return Airflow Rate in a Variable Air Volume System

Pressure differences in the envelope of a building result in leakage airflow (i.e., the unintended flow of air). This can lead to increased building heating and cooling energy, decreased thermal comfort for occupants, and the spread of moisture. To address this problem, it is necessary to know the leakage airflow in a building. Generally, the leakage airflow in a building is calculated by determining the leakage function through fan pressurization methods, such as the blower door test, and substituting the pressure difference measured by the pressure sensor. However, it is difficult to install continuous pressure sensors in an operating building. Therefore, this study proposes a method to utilize the supply and return airflow of an air conditioning system to predict the variation in the leakage airflow with changing indoor and outdoor airflow, and the efficacy of this approach was verified through experiments. The experiment measured the indoor and outdoor pressure difference of the building with a change in the speed of the supply and return fans and the opening rate of the variable air volume (VAV) damper. As a result of the experiment, the indoor–outdoor pressure difference is proportional to the difference between the indoor supply airflow and the ventilation airflow. In addition, the relationship between the pressure difference and the leakage airflow was derived through the pressurization/decompression method using an air handler, and the leakage airflow from the pressure difference generated by the operation of the air conditioning system was calculated. Lastly, the relationship between the supply and return airflow difference and the leakage airflow was derived based on the experimental results, and the leakage airflow was predicted based on the relationship.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-11-11
DOI
https://doi.org/10.3390/app142210363
Citations
1
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Prediction of the Leakage Airflow Rate Using the Supply and Return Airflow Rate in a Variable Air Volume System

Young-Hum Cho, Jin-Hyun Lee, Kyung Won Kim, Hyo-Jun Kim
1 citations
Applied Sciences
Wind and Air Flow Studies
0.21
article

The Prediction of the Leakage Airflow Rate Using the Supply and Return Airflow Rate in a Variable Air Volume System

Young-Hum Cho, Jin-Hyun Lee, Kyung Won Kim, Hyo-Jun Kim
article en
1 citations

Abstract

Pressure differences in the envelope of a building result in leakage airflow (i.e., the unintended flow of air). This can lead to increased building heating and cooling energy, decreased thermal comfort for occupants, and the spread of moisture. To address this problem, it is necessary to know the leakage airflow in a building. Generally, the leakage airflow in a building is calculated by determining the leakage function through fan pressurization methods, such as the blower door test, and substituting the pressure difference measured by the pressure sensor. However, it is difficult to install continuous pressure sensors in an operating building. Therefore, this study proposes a method to utilize the supply and return airflow of an air conditioning system to predict the variation in the leakage airflow with changing indoor and outdoor airflow, and the efficacy of this approach was verified through experiments. The experiment measured the indoor and outdoor pressure difference of the building with a change in the speed of the supply and return fans and the opening rate of the variable air volume (VAV) damper. As a result of the experiment, the indoor–outdoor pressure difference is proportional to the difference between the indoor supply airflow and the ventilation airflow. In addition, the relationship between the pressure difference and the leakage airflow was derived through the pressurization/decompression method using an air handler, and the leakage airflow from the pressure difference generated by the operation of the air conditioning system was calculated. Lastly, the relationship between the supply and return airflow difference and the leakage airflow was derived based on the experimental results, and the leakage airflow was predicted based on the relationship.

Applied SciencesVol. 14(22)
Yeungnam University (KR)
National Research Foundation, National Research Foundation of Korea, Ministry of Science and ICT, South Korea
Affordable and clean energy
Openalex Percentile: Top 49%
Wind and Air Flow Studies
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.