Endoscopic In Vivo Hyperspectral Imaging for Head and Neck Tumor Surgeries Using a Medically Approved CE-Certified Camera with Rapid Visualization During Surgery

<b>Background</b>: In vivo visualization of malignant tumors remains the main challenge during head and neck cancer surgery. This can result in inadequate tumor margin assessment and incomplete tumor resection, adversely affecting patient outcomes. Hyperspectral imaging (HSI) is a promising approach to address this issue. However, its application in surgery has been limited by the lack of medically approved HSI devices compliant with MDR regulations, as well as challenges regarding the integration into the surgical workflow. <b>Methods</b>: In this feasibility study, we employed endoscopic HSI during surgery to visualize the tumor sites of 12 head and neck cancer patients. We optimized the HSI workflow to minimize time required during surgery and to reduce the adaptation period needed for surgeons to adjust to the new workflow. Additionally, we implemented data processing to enable real-time classification and visualization of HSI within the intraoperative setting. HSI evaluation was conducted using principal component analysis and k-means clustering, with this clustering validated through comparison with expert annotations. <b>Results</b>: Our complete HSI workflow requires two to three minutes, with each HSI measurement-including evaluation and visualization-taking less than 10 s, achieving an accuracy of 79%, sensitivity of 72%, and specificity of 84%. Medical personnel became proficient with the HSI system after two surgeries. <b>Conclusions</b>: This study presents an HSI workflow for in vivo tissue differentiation during head and neck cancer surgery, providing accurate and visually accessible results within minimal time. This approach enhances the in vivo evaluation of tumor margins, leading to more clear margins and, consequently, improved patient outcomes.

Authors

Institutions

Publication Details

Journal
Cancers
Published
2024-11-10
DOI
https://doi.org/10.3390/cancers16223785
Citations
8
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
1.48

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Endoscopic In Vivo Hyperspectral Imaging for Head and Neck Tumor Surgeries Using a Medically Approved CE-Certified Camera with Rapid Visualization During Surgery

Nadja Ziller, Jonas Ballmaier, Thomas Bitter, David Pertzborn et al.
8 citations
Cancers
Photoacoustic and Ultrasonic Imaging
1.48
article

Endoscopic In Vivo Hyperspectral Imaging for Head and Neck Tumor Surgeries Using a Medically Approved CE-Certified Camera with Rapid Visualization During Surgery

Nadja Ziller, Jonas Ballmaier, Thomas Bitter, David Pertzborn, G Schneider, Theresa Werner, Anna Mühlig, Mussab Kouka, Orlando Guntinas‐Lichius, Ferdinand von Eggeling, Ayman Bali, Marcela Mafra
article en
8 citations

Abstract

<b>Background</b>: In vivo visualization of malignant tumors remains the main challenge during head and neck cancer surgery. This can result in inadequate tumor margin assessment and incomplete tumor resection, adversely affecting patient outcomes. Hyperspectral imaging (HSI) is a promising approach to address this issue. However, its application in surgery has been limited by the lack of medically approved HSI devices compliant with MDR regulations, as well as challenges regarding the integration into the surgical workflow. <b>Methods</b>: In this feasibility study, we employed endoscopic HSI during surgery to visualize the tumor sites of 12 head and neck cancer patients. We optimized the HSI workflow to minimize time required during surgery and to reduce the adaptation period needed for surgeons to adjust to the new workflow. Additionally, we implemented data processing to enable real-time classification and visualization of HSI within the intraoperative setting. HSI evaluation was conducted using principal component analysis and k-means clustering, with this clustering validated through comparison with expert annotations. <b>Results</b>: Our complete HSI workflow requires two to three minutes, with each HSI measurement-including evaluation and visualization-taking less than 10 s, achieving an accuracy of 79%, sensitivity of 72%, and specificity of 84%. Medical personnel became proficient with the HSI system after two surgeries. <b>Conclusions</b>: This study presents an HSI workflow for in vivo tissue differentiation during head and neck cancer surgery, providing accurate and visually accessible results within minimal time. This approach enhances the in vivo evaluation of tumor margins, leading to more clear margins and, consequently, improved patient outcomes.

CancersVol. 16(22)
Comprehensive Cancer Center Mainfranken (DE), Jena University Hospital (DE)
Carl-Zeiss-Stiftung, European Commission, Bundesministerium für Bildung und Forschung
Openalex Percentile: Top 19%
Photoacoustic and Ultrasonic Imaging
1.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.