BRET Nano Q-Body: A Nanobody-Based Ratiometric Bioluminescent Immunosensor for Point-of-Care Testing

We developed a nanobody-based homogeneous bioluminescent immunosensor to achieve a one-pot detection for point-of-care testing (POCT). This immunosensor was named BRET nano Q-body as its emission color changes via bioluminescence resonance energy transfer (BRET) upon antigen addition. NanoLuc luciferase and a cysteine-containing tag were fused to the N-terminus of the nanobody, which was labeled with a fluorescent dye via thiol-maleimide Michael addition. The nanobody employed in this proof-of-principle experiment recognizes methotrexate (MTX), a chemotherapeutic agent. After optimizing the fluorescent dye and linker, the BRET nano Q-body dose-dependently exhibited a greater than 7-fold increase in emission ratio (TAMRA/NanoLuc). Moreover, we found its superior thermostability endurance in organic solvents, reducing agents, and detergents due to the robust structure of nanobody, as well as accommodation in biological fluids, such as milk, serum, and whole blood without dilution, with limits of detection of 0.50, 1.6, and 3.7 nM, respectively. Furthermore, the BRET nano Q-body was subjected to lyophilization and fabricated into a paper device, which markedly improved its portability and enabled more than one month of storage at 25 °C. The paper device also performed appropriate functions in the biological fluids without any dilution and can be used for on-site therapeutic drug monitoring of MTX. Altogether, we developed a powerful tool, the BRET nano Q-body, for POCT, and demonstrated its applicability in several biological fluids. In addition, we confirmed the feasibility of paper devices, which are expected to be transformative for in situ detection in therapeutic, diagnostic, and environmental applications.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2024-11-11
DOI
https://doi.org/10.1021/acssensors.4c01800
Citations
12
Primary Topic
bioluminescence and chemiluminescence research
Type
article
Field-Weighted Citation Impact
2.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

BRET Nano Q-Body: A Nanobody-Based Ratiometric Bioluminescent Immunosensor for Point-of-Care Testing

Hiroshi Ueda, Akihito Inoue, Yinghui Yang, Tetsuya Kitaguchi et al.
12 citations
ACS Sensors
bioluminescence and chemiluminescence research
2.81
article

BRET Nano Q-Body: A Nanobody-Based Ratiometric Bioluminescent Immunosensor for Point-of-Care Testing

Hiroshi Ueda, Akihito Inoue, Yinghui Yang, Tetsuya Kitaguchi, Takanobu Yasuda, Bo Zhu
article en
12 citations

Abstract

We developed a nanobody-based homogeneous bioluminescent immunosensor to achieve a one-pot detection for point-of-care testing (POCT). This immunosensor was named BRET nano Q-body as its emission color changes via bioluminescence resonance energy transfer (BRET) upon antigen addition. NanoLuc luciferase and a cysteine-containing tag were fused to the N-terminus of the nanobody, which was labeled with a fluorescent dye via thiol-maleimide Michael addition. The nanobody employed in this proof-of-principle experiment recognizes methotrexate (MTX), a chemotherapeutic agent. After optimizing the fluorescent dye and linker, the BRET nano Q-body dose-dependently exhibited a greater than 7-fold increase in emission ratio (TAMRA/NanoLuc). Moreover, we found its superior thermostability endurance in organic solvents, reducing agents, and detergents due to the robust structure of nanobody, as well as accommodation in biological fluids, such as milk, serum, and whole blood without dilution, with limits of detection of 0.50, 1.6, and 3.7 nM, respectively. Furthermore, the BRET nano Q-body was subjected to lyophilization and fabricated into a paper device, which markedly improved its portability and enabled more than one month of storage at 25 °C. The paper device also performed appropriate functions in the biological fluids without any dilution and can be used for on-site therapeutic drug monitoring of MTX. Altogether, we developed a powerful tool, the BRET nano Q-body, for POCT, and demonstrated its applicability in several biological fluids. In addition, we confirmed the feasibility of paper devices, which are expected to be transformative for in situ detection in therapeutic, diagnostic, and environmental applications.

ACS SensorsVol. 9(11)
Life Science Institute (JP), Institute of Science Tokyo (JP)
Japan Society for the Promotion of Science, Japan Science and Technology Agency
Openalex Percentile: Top 9%
bioluminescence and chemiluminescence research
2.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.