Real-Time Estimation of CO2 Absorption Capacity Using Ionic Conductivity of Protonated Di-Methyl-Ethanolamine (DMEA) and Electrical Conductivity in Low-Concentration DMEA Aqueous Solutions

The present study investigates the real-time estimation of CO2 absorption capacity (CAC) based on the electrical conductivity (EC) of low-concentration di-methyl-ethanolamine (DMEA) solutions (0.1–0.5 M). CO2 absorption experiments are conducted to measure the variation in CAC and EC during CO2 absorption, revealing a strong correlation between the two properties. The ionic conductivity of DMEAH+ formed during absorption is calculated to be 53.1 S·cm2/(mol·z), which is found to be larger than that of TEAH+ and MDEAH+. This can be attributed to the smaller molar mass and higher ionic mobility of DMEAH+. A significant finding is that the measured EC (ECM) of the DMEA solutions consistently demonstrates a lower value than the theoretically predicted value. This discrepancy is due to the larger ionic size of DMEAH+, which results in a reduction in the real mean ionic activity coefficient. This effect becomes more pronounced with increasing DMEA concentration. Consequently, a higher CAC is required to produce the same change in EC at higher amine concentrations. Based on these findings, an empirical equation is devised to estimate CAC from ECM in solutions of constant DMEA concentration. This equation will be employed as a practical approach for the in situ monitoring of CO2 absorption using DMEA aqueous solution.

Authors

Institutions

Publication Details

Journal
Processes
Published
2024-11-10
DOI
https://doi.org/10.3390/pr12112495
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Estimation of CO2 Absorption Capacity Using Ionic Conductivity of Protonated Di-Methyl-Ethanolamine (DMEA) and Electrical Conductivity in Low-Concentration DMEA Aqueous Solutions

Jin Han, Sang‐Jun Han, Jung‐Ho Wee
Processes
Analytical Chemistry and Sensors
article

Real-Time Estimation of CO2 Absorption Capacity Using Ionic Conductivity of Protonated Di-Methyl-Ethanolamine (DMEA) and Electrical Conductivity in Low-Concentration DMEA Aqueous Solutions

Jin Han, Sang‐Jun Han, Jung‐Ho Wee
article en

Abstract

The present study investigates the real-time estimation of CO2 absorption capacity (CAC) based on the electrical conductivity (EC) of low-concentration di-methyl-ethanolamine (DMEA) solutions (0.1–0.5 M). CO2 absorption experiments are conducted to measure the variation in CAC and EC during CO2 absorption, revealing a strong correlation between the two properties. The ionic conductivity of DMEAH+ formed during absorption is calculated to be 53.1 S·cm2/(mol·z), which is found to be larger than that of TEAH+ and MDEAH+. This can be attributed to the smaller molar mass and higher ionic mobility of DMEAH+. A significant finding is that the measured EC (ECM) of the DMEA solutions consistently demonstrates a lower value than the theoretically predicted value. This discrepancy is due to the larger ionic size of DMEAH+, which results in a reduction in the real mean ionic activity coefficient. This effect becomes more pronounced with increasing DMEA concentration. Consequently, a higher CAC is required to produce the same change in EC at higher amine concentrations. Based on these findings, an empirical equation is devised to estimate CAC from ECM in solutions of constant DMEA concentration. This equation will be employed as a practical approach for the in situ monitoring of CO2 absorption using DMEA aqueous solution.

ProcessesVol. 12(11)
Catholic University of Korea (KR)
National Research Foundation, National Research Foundation of Korea, Ministry of Science and ICT, South Korea
Clean water and sanitation
Openalex Percentile: Top 80%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.