Numerical Simulation of the Diffusion Characteristics of Odor Pollutants of Waste Bunkers in Waste Incineration Plant

This paper utilizes the waste bunker of a waste incineration plant as the analysis model. It analyzes the airflow characteristics under various unloading door opening states and the air flow velocity through CFD simulation. The simulation analysis results show that when one unloading door is opened, it is recommended to adjust the opening amplitude or set an air outlet to optimize the airflow distribution. If two unloading doors are opened, it is advised to prioritize the two middle unloading doors (M4, M5) or the two rightmost doors (M7, M8). Furthermore, the exhaust port located relatively far from the unloading door should be closed to reduce the turbulence of the airflow. When all unloading doors are opened, the air flow velocity at the unloading door needs to be increased to achieve an efficient exhaust effect and prevent negative pressure problems at low speed. The results offer theoretical support for odor control technologies and provide valuable design recommendations for air outlets and unloading doors in municipal waste incineration plants. Additionally, this study proposes optimization strategies and effective solutions for addressing odor pollutant diffusion in waste incineration facilities.

Authors

Institutions

Publication Details

Journal
Processes
Published
2024-11-11
DOI
https://doi.org/10.3390/pr12112502
Citations
1
Primary Topic
Industrial Gas Emission Control
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Simulation of the Diffusion Characteristics of Odor Pollutants of Waste Bunkers in Waste Incineration Plant

Lingxia Zhu, Jianjun Cai, Hao Wu, Minjia Guo et al.
1 citations
Processes
Industrial Gas Emission Control
0.21
article

Numerical Simulation of the Diffusion Characteristics of Odor Pollutants of Waste Bunkers in Waste Incineration Plant

Lingxia Zhu, Jianjun Cai, Hao Wu, Minjia Guo, Qiuxia Wei
article en
1 citations

Abstract

This paper utilizes the waste bunker of a waste incineration plant as the analysis model. It analyzes the airflow characteristics under various unloading door opening states and the air flow velocity through CFD simulation. The simulation analysis results show that when one unloading door is opened, it is recommended to adjust the opening amplitude or set an air outlet to optimize the airflow distribution. If two unloading doors are opened, it is advised to prioritize the two middle unloading doors (M4, M5) or the two rightmost doors (M7, M8). Furthermore, the exhaust port located relatively far from the unloading door should be closed to reduce the turbulence of the airflow. When all unloading doors are opened, the air flow velocity at the unloading door needs to be increased to achieve an efficient exhaust effect and prevent negative pressure problems at low speed. The results offer theoretical support for odor control technologies and provide valuable design recommendations for air outlets and unloading doors in municipal waste incineration plants. Additionally, this study proposes optimization strategies and effective solutions for addressing odor pollutant diffusion in waste incineration facilities.

ProcessesVol. 12(11)
Central South University (CN), Guilin University of Electronic Technology (CN)
National Natural Science Foundation of China, China Postdoctoral Science Foundation, Guilin Science and Technology Bureau
Openalex Percentile: Top 50%
Industrial Gas Emission Control
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.