Uncommon Cardiac Perforation and Lead Displacement After Pacemaker Implantation: A Case Study and Diagnostic Insights

BACKGROUND Pacemaker implantation serves as a prevalent therapeutic approach for bradycardia or atrioventricular blocks associated with syncope. While generally regarded as safe, this procedure is not devoid of rare yet severe complications. Examples include lead-induced cardiac perforation resulting in pneumothorax or pericardial effusion, which pose life-threatening risks. CASE REPORT This article presents a case study detailing the experience of an 87-year-old patient diagnosed with complete atrioventricular block who underwent permanent pacemaker implantation, complicated by lead displacement and cardiac perforation. Despite the absence of typical post-implantation symptoms, such as backache, chest tightness, shortness of breath, and drops in blood pressure, the electrocardiogram (ECG) revealed a right bundle-branch block pattern. Additionally, bradycardia and occasional pacemaker capture failure were observed the day following pacemaker implantation. Subsequent X-ray and computer tomography examinations confirmed displacement of the ventricular lead and the presence of cardiac perforation and left pneumothorax. Following emergent thoracic drainage and repositioning of the right ventricular lead, the patient was discharged without further complications. CONCLUSIONS This case highlights the importance of thorough post-implantation monitoring, even in the absence of typical symptoms. Early detection through electrocardiogram, X-ray, and CT can facilitate timely intervention, as demonstrated by the successful treatment and discharge of the patient following emergent thoracic drainage and pacemaker lead repositioning.

Authors

Institutions

Publication Details

Journal
American Journal of Case Reports
Published
2024-11-05
DOI
https://doi.org/10.12659/ajcr.945008
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncommon Cardiac Perforation and Lead Displacement After Pacemaker Implantation: A Case Study and Diagnostic Insights

Chyi Lo, Pei‐Yun Chen, Ying-Ying Huang, Yen‐Nien Lin
American Journal of Case Reports
Orthopaedic implants and arthroplasty
article

Uncommon Cardiac Perforation and Lead Displacement After Pacemaker Implantation: A Case Study and Diagnostic Insights

Chyi Lo, Pei‐Yun Chen, Ying-Ying Huang, Yen‐Nien Lin
article en

Abstract

BACKGROUND Pacemaker implantation serves as a prevalent therapeutic approach for bradycardia or atrioventricular blocks associated with syncope. While generally regarded as safe, this procedure is not devoid of rare yet severe complications. Examples include lead-induced cardiac perforation resulting in pneumothorax or pericardial effusion, which pose life-threatening risks. CASE REPORT This article presents a case study detailing the experience of an 87-year-old patient diagnosed with complete atrioventricular block who underwent permanent pacemaker implantation, complicated by lead displacement and cardiac perforation. Despite the absence of typical post-implantation symptoms, such as backache, chest tightness, shortness of breath, and drops in blood pressure, the electrocardiogram (ECG) revealed a right bundle-branch block pattern. Additionally, bradycardia and occasional pacemaker capture failure were observed the day following pacemaker implantation. Subsequent X-ray and computer tomography examinations confirmed displacement of the ventricular lead and the presence of cardiac perforation and left pneumothorax. Following emergent thoracic drainage and repositioning of the right ventricular lead, the patient was discharged without further complications. CONCLUSIONS This case highlights the importance of thorough post-implantation monitoring, even in the absence of typical symptoms. Early detection through electrocardiogram, X-ray, and CT can facilitate timely intervention, as demonstrated by the successful treatment and discharge of the patient following emergent thoracic drainage and pacemaker lead repositioning.

American Journal of Case ReportsVol. 25
China Medical University (TW), China Medical University Hospital (TW), Kang-Ning Junior College of Medical Care and Management (TW)
Openalex Percentile: Top 62%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.