Eliminating metal artifacts in dental computed tomography using an elaborate sinogram normalization interpolation method with CNR-based metal segmentation

Abstract Metal artifact reduction (MAR) in dental cone-beam computed tomography (CBCT) is critical for improving its clinical usefulness and remains a challenging problem. This study presents an elaborate sinogram normalization interpolation (SNI) method with contrast-to-noise ratio (CNR)-based metal segmentation to eliminate metal artifacts in dental CBCT. The proposed MAR method involves three main steps: (1) CNR-based segmentation of a metal trace in the sinogram domain; (2) generation of a residual artifact-reduced prior sinogram; and (3) sinogram completion using the prior sinogram, followed by filtered-backprojection (FBP)-based CBCT reconstruction and metal insertion processes. To verify the efficacy of the proposed method, simulations and experiments were performed using numerical and physical dental phantoms with several metal inserts. The quality of the resulting CBCT images was quantitatively evaluated using the structural similarity (SSIM) metric and compared to those obtained with other interpolation-based MAR methods. A tabletop setup for the micro-CT system was used in the experiment, which comprised an X-ray tube operated under tube conditions of 70 kV p and 5 mA and a flat-panel detector with a pixel size of 198 μm. Our results indicate that the CNR-based metal segmentation method precisely identified traces of metallic objects on the sinogram, and thereby, the proposed SNI-based MAR method considerably reduced metal artifacts in dental CBCT images without introducing any contrast anomalies. The SSIM values of the CBCT images obtained with the proposed MAR method were 0.99 and 0.95 for the simulation and experiment, respectively, which are approximately 11% and 9% greater than those with a simple threshold-based linear interpolation method, respectively, improving the image quality. The proposed MAR method can be applied to reduce metal artifacts in real-world dental CBCT systems.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-11-01
DOI
https://doi.org/10.1088/1748-0221/19/11/c11003
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Eliminating metal artifacts in dental computed tomography using an elaborate sinogram normalization interpolation method with CNR-based metal segmentation

Duhee Jeon, Hyosung Cho, Sung‐Min Park, Woosung Kim et al.
1 citations
Journal of Instrumentation
Advanced X-ray and CT Imaging
0.18
article

Eliminating metal artifacts in dental computed tomography using an elaborate sinogram normalization interpolation method with CNR-based metal segmentation

Duhee Jeon, Hyosung Cho, Sung‐Min Park, Woosung Kim, Soohyun Lee, Young-Hwan Lim
article en
1 citations

Abstract

Abstract Metal artifact reduction (MAR) in dental cone-beam computed tomography (CBCT) is critical for improving its clinical usefulness and remains a challenging problem. This study presents an elaborate sinogram normalization interpolation (SNI) method with contrast-to-noise ratio (CNR)-based metal segmentation to eliminate metal artifacts in dental CBCT. The proposed MAR method involves three main steps: (1) CNR-based segmentation of a metal trace in the sinogram domain; (2) generation of a residual artifact-reduced prior sinogram; and (3) sinogram completion using the prior sinogram, followed by filtered-backprojection (FBP)-based CBCT reconstruction and metal insertion processes. To verify the efficacy of the proposed method, simulations and experiments were performed using numerical and physical dental phantoms with several metal inserts. The quality of the resulting CBCT images was quantitatively evaluated using the structural similarity (SSIM) metric and compared to those obtained with other interpolation-based MAR methods. A tabletop setup for the micro-CT system was used in the experiment, which comprised an X-ray tube operated under tube conditions of 70 kV p and 5 mA and a flat-panel detector with a pixel size of 198 μm. Our results indicate that the CNR-based metal segmentation method precisely identified traces of metallic objects on the sinogram, and thereby, the proposed SNI-based MAR method considerably reduced metal artifacts in dental CBCT images without introducing any contrast anomalies. The SSIM values of the CBCT images obtained with the proposed MAR method were 0.99 and 0.95 for the simulation and experiment, respectively, which are approximately 11% and 9% greater than those with a simple threshold-based linear interpolation method, respectively, improving the image quality. The proposed MAR method can be applied to reduce metal artifacts in real-world dental CBCT systems.

Journal of InstrumentationVol. 19(11)
Yonsei University (KR)
Openalex Percentile: Top 51%
Advanced X-ray and CT Imaging
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.